MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jfma.2024.10.008

Медицинская библиотека · Journal of the Formosan Medical Association = Taiwan yi zhi · 2024

Simplified dual-time-point 99mTc-pyrophosphate scintigraphy in patients with suspected transthyretin amyloid cardiomyopathy: A single center series.

Shih Yi-San, Wang Shan-Ying, Tzeng Bing-Hsiean, Chuang Wen-Po, Wu Yen-Wen

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

There is a lack of consensus regarding the optimal imaging time points and imaging techniques between planar and/or single-photon emission computed tomography (SPECT)/computed tomography (CT) acquisitions for technetium-99 m pyrophosphate (99mTc-PYP) cardiac scintigraphy. The aim of this study was to investigate correlations between planar and SPECT/CT images and between 1-h and 3-h imaging time points.

METHODS

We retrospectively analyzed consecutive patients with clinically suspected transthyretin amyloid cardiomyopathy who underwent 99mTc-PYP scintigraphy from November 1, 2019 to November 30, 2022. Visual scores were compared between 1- and 3-h imaging time points and between planar and SPECT/CT acquisitions.

RESULTS

A total of 100 patients (66% male; mean age, 65 years) were included, and 1- and 3-h planar and SPECT/CT images were obtained for 97 patients. There was a significant difference in visual grading scores between 1- and 3-h time points on both planar and SPECT/CT imaging, with a downgrade in score in 61 of 99 (61%) cases on planar imaging, and in 14 of 97 (14%) cases on SPECT/CT imaging (p < 0.001). There were significant differences in visual grading scores between planar and SPECT/CT imaging at both time points, with cases being scored higher on planar imaging than on SPECT/CT imaging (81/97 cases for 1-h imaging, and 50/97 cases for 3-h imaging) (p < 0.001).

CONCLUSION

Simplified 1-h SPECT/CT imaging with visual score and selective use of 3-h SPECT/CT imaging may be an efficient protocol and may reduce the potential for over-scoring and equivocal interpretation. Further validation in larger and more diverse populations is needed.

Для цитирования: Shih Yi-San, Wang Shan-Ying, Tzeng Bing-Hsiean, Chuang Wen-Po, Wu Yen-Wen. Simplified dual-time-point 99mTc-pyrophosphate scintigraphy in patients with suspected transthyretin amyloid cardiomyopathy: A single center series.. Journal of the Formosan Medical Association = Taiwan yi zhi. 2024. DOI: 10.1016/j.jfma.2024.10.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.