Longitudinal Changes in Optical Quality, Spatial Vision, and Depth Vision after Laser Refractive Surgery for Myopia.

Sarkar Samrat, Bharadwaj Shrikant R, Reddy Jagadesh C, Vaddavalli Pravin K

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

SIGNIFICANCE: Laser refractive surgery procedures are efficacious at correcting myopia, but they result in long-term deterioration of optical quality that affects monocular and binocular visual performance. The study shows that the optical quality of the two eyes needs to be similar to optimize binocular visual performance after surgery.

PURPOSE: This study aimed to systematically analyze longitudinal changes in optical quality, high- and low-contrast logMAR acuity and random-dot stereoacuity before and after three refractive surgery procedures for correcting myopia.

METHODS

A total of 106 subjects (laser-assisted in situ keratomileusis, 40; photorefractive keratectomy, 26; small-incision lenticule extraction, 40) with myopia and astigmatism ≤1.5 D participated in this prospective cohort-based study. All aforementioned outcome variables were measured in both eyes pre-operatively and 1 week and 1, 3, and 6 months post-operatively.

RESULTS

Pre-operative myopic spherical equivalent of refraction (median [25th to 75th interquartile range], -6.4 D [-8.0 to -4.2 D] for laser-assisted in situ keratomileusis, -4.3 D [-5.0 to -3.5 D] for photorefractive keratectomy, -5.5 D [-6.5 to -4.3 D] for small-incision lenticule extraction) was corrected to within ±0.75 D of emmetropia in all cohorts up to 6 months post-operatively (P < .001). Higher-order wavefront aberrations, uncorrected high- and low-contrast logMAR acuity, and stereoacuity all worsened and remained so up to 6 months post-operatively, relative to pre-operative values (P < .001). Stereoacuity worsened with both interocular average and difference in the magnitude of higher-order aberrations, whereas logMAR acuities worsened only with interocular average of these aberrations (r ≥ 0.40; P < .01 for all).

CONCLUSIONS

Although the refractive surgery procedures tested here correct myopia, they result in a sustained (up to 6 months) loss of optical quality and spatial and depth-related visual functions post-operatively. Both interocular average and difference in the eye's optical quality seem to impair binocular visual functions after refractive surgery for myopia.

Для цитирования: Sarkar Samrat, Bharadwaj Shrikant R, Reddy Jagadesh C, Vaddavalli Pravin K. Longitudinal Changes in Optical Quality, Spatial Vision, and Depth Vision after Laser Refractive Surgery for Myopia.. Optometry and vision science : official publication of the American Academy of Optometry. 2020. DOI: 10.1097/opx.0000000000001513.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.