Automated refraction after trifocal and trifocal toric intraocular lens implantation.

Rementería-Capelo Laureano A, García-Pérez Jorge L, Contreras Inés, Blázquez Vanesa, Ruiz-Alcocer Javier

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To analyze the correlation between automated refraction and manifest refraction after implantation of a trifocal intraocular lens or its toric version.

METHODS

This cross-sectional study involved 105 eyes of 105 patients. Subjects were divided in two groups: 62 with trifocal (AcrySof PanOptix) and 43 with trifocal toric (AcrySof PanOptix Toric) intraocular lenses. Automated refraction was employed as starting point for obtaining the manifest refraction. Automated refraction and manifest refraction measurements were analyzed and compared using the vector analysis 3 months after the surgery.

RESULTS

In both groups, the higher differences between automated refraction and manifest refraction measurements were found for the cylinder and the spherical equivalent (M). Cylinder values for PanOptix were: -0.60 ± 0.36 D with automated refraction and -0.17 ± 38 D with manifest refraction (p < 0.001); for PanOptix Toric, the values were: -0.49 ± 0.31 D with automated refraction and -0.05 ± 0.21 D with manifest refraction (p < 0.001). M values for PanOptix were: -0.23 ± 0.31 D with automated refraction and -0.03 ± 0.16 D with manifest refraction (p < 0.001); for PanOptix Toric, the values were: -0.13 ± 0.40 D with automated refraction and 0.01 ± 0.12 D with manifest refraction (p < 0.001). For the PanOptix group, intraclass correlation coefficients were: 0.51 (sphere), 0.64 (cylinder), 0.42 (M), 0.62 (J0), and 0.37 (J45). For the PanOptix Toric group, the intraclass correlation coefficients were: 0.39 (sphere), 0.61 (cylinder), 0.39 (M), 0.53 (J0), and 0.09 (J45).

CONCLUSION

The results of this study suggest that patients implanted with the trifocal and the trifocal toric intraocular lens under study showed similar automated refraction results between them, with a slight trend to more negative amounts of cylinder and M. Nevertheless, clinicians should carefully confirm all parameters of the refraction with manifest refraction.

Для цитирования: Rementería-Capelo Laureano A, García-Pérez Jorge L, Contreras Inés, Blázquez Vanesa, Ruiz-Alcocer Javier. Automated refraction after trifocal and trifocal toric intraocular lens implantation.. European journal of ophthalmology. 2020. DOI: 10.1177/1120672120914848.