MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_987_19

Медицинская библиотека · Indian journal of ophthalmology · 2020

Verion digital marking versus smartphone-assisted manual marking and isolated manual marking in toric intraocular lens implantation.

Khatib Zain Irfan, Haldipurkar Suhas S, Shetty Vijay

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the accuracy of isolated manual marking and smartphone-assisted manual marking with the Verion image-guided system for toric intraocular lens (IOL) implantation.

METHODS

In this prospective observational study, 42 eyes of 36 patients planned for phacoemulsification with toric IOL implantation with corneal astigmatism >1D as measured on Lenstar LS 900 optical biometer were included. Patients were preoperatively registered and photographed on the Verion image-guided system. In the operating room, the patient's eye was manually marked at the 6 o' clock limbus (Manual axis-90°) on slit-lamp in sitting position. Next, using the smartphone android app-iToric Patwardhan, the exact mark axis was confirmed (Smartphone axis). Following this, the patient was taken on the operation table where the mark axis was confirmed with Verion digital overlay on an external screen (Verion axis). The absolute angular deviation of manual axis from Verion was compared with the absolute angular deviation of the smartphone axis from Verion as the primary outcome measure.

RESULTS

The mean absolute angular deviation between the smartphone axis and the Verion axis was 2.62°, which was significantly lower (P < 0.05) than that between the manual axis and Verion axis (4.60°). Moreover, the intraclass correlation coefficient between the smartphone axis and Verion axis was 0.88 indicating a strong agreement between the two.

CONCLUSION

Smartphone-assisted manual marking significantly improves the accuracy of manual marking alone when comparing with the Verion Digital Marker system for toric IOL implantation.

Для цитирования: Khatib Zain Irfan, Haldipurkar Suhas S, Shetty Vijay. Verion digital marking versus smartphone-assisted manual marking and isolated manual marking in toric intraocular lens implantation.. Indian journal of ophthalmology. 2020. DOI: 10.4103/ijo.ijo_987_19.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.