MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2019.08.009

Медицинская библиотека · Journal of cataract and refractive surgery · 2019

Kinetic visual acuity, stereopsis, and ocular deviation with an implantable collamer lens.

Kato Sayaka, Shimizu Kimiya, Igarashi Akihito, Kawamorita Takushi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare kinetic visual acuity, stereopsis, ocular deviation, and fusion amplitude before and after implantable collamer lens (ICL) surgery.

SETTING

Sanno Hospital.

DESIGN

Retrospective analysis.

METHODS

The charts of adult patients who underwent implantation of an ICL with a central aquaport (V4c) for emmetropia were reviewed. The mean preoperative spherical equivalent and subjective astigmatism were -7.87 diopters (D) ± 3.13 (SD) and -0.75 ± 0.78 D, respectively. All measurements were obtained with full refraction before surgery and without spectacle correction after surgery. The kinetic visual acuity was measured with the AS-4D device. Stereopsis and ocular deviation were measured with the Titmus Stereotest and an alternate prism cover test, respectively. Fusion amplitude was determined from breakpoints measured using a prism.

RESULTS

The study comprised 29 adult patients (58 eyes). One month postoperatively, the mean safety and efficacy indices were 1.13 ± 0.20 and 0.96 ± 0.25, respectively, and 57 eyes (98.7%) were within ±0.5 D of the target correction. The mean kinetic visual acuity (logarithm of the minimum angle of resolution) was 0.30 ± 0.21 preoperatively and 0.20 ± 0.15 (Snellen 20/40 versus 20/32) postoperatively and the mean stereopsis (seconds of arc), 48.5 ± 1.6 versus 41.5 ± 1.1; both improved significantly (P < .001 and P = .012, respectively). The mean distance ocular deviation (-4.0 ± 3.8 prism diopters [Δ] versus 2.8 ± 3.6 Δ; P = .002) and near ocular deviation (-6.5 ± 6.7 Δ versus 5.4 ± 6.9 Δ; P = .04) decreased significantly. The fusion amplitude increased for near vision only.

CONCLUSIONS

ICL implantation improved kinetic visual acuity and stereopsis, decreased ocular deviation, and increased near fusion amplitude.

Для цитирования: Kato Sayaka, Shimizu Kimiya, Igarashi Akihito, Kawamorita Takushi. Kinetic visual acuity, stereopsis, and ocular deviation with an implantable collamer lens.. Journal of cataract and refractive surgery. 2019. DOI: 10.1016/j.jcrs.2019.08.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.