DOI 10.3928/1081597x-20190930-02
SMILE, Topography-Guided LASIK, and Wavefront-Guided LASIK: Review of Clinical Outcomes in Premarket Approval FDA Studies.
Аннотация
PURPOSE: To review clinical outcomes of the U.S. Food and Drug Administration premarket approval (PMA) studies of the three recently approved refractive surgery platforms for the correction of spherocylindrical myopia.
METHODS
Clinical outcomes and vector analysis of astigmatism were reviewed and compared between wavefront-guided laser in situ keratomileusis (LASIK) (WFG group) (STAR S4 IR with iDesign aberrometer; Johnson & Johnson Vision Care, Inc., Santa Ana, CA), topography-guided LASIK (TOPO group) (Allegretto Wave Eye-Q laser; Alcon Laboratories, Inc., Fort Worth, TX), and small incision lenticule extraction (SMILE group) (VisuMax laser; Carl Zeiss Meditec AG, Jena, Germany).
RESULTS
The number of eyes included was 304, 249, and 334 for the SMILE, TOPO, and WFG groups, respectively. The WFG group had the highest preoperative spherical equivalent refraction (-6.21 ± 2.78 diopters [D]), followed by the SMILE (-5.39 ± 2.30 D) and TOPO (-4.61 ± 2.43 D) groups. At 6 months postoperatively, 83.7%, 88.9%, and 82.6% of eyes in the SMILE, TOPO, and WFG groups, respectively, had uncorrected distance visual acuity (UDVA) of 20/20 or better. SMILE showed slower visual recovery at early postoperative examinations, whereas the WFG group had a decrease in UDVA over time due to refractive regression. The mean refractive cylinder changed from -1.53 ± 0.70 D preoperatively to -0.22 ± 0.33 D at 6 months postoperatively in the SMILE group, -1.19 ± 1.23 to -0.19 ± 0.30 D in the TOPO group, and -1.77 ± 1.65 to -0.33 ± 0.36 D in the WFG group. With all three procedures, undercorrection of refractive cylinder was seen with increasing attempted correction.
CONCLUSIONS
All three procedures demonstrated excellent outcomes, considering differences in attempted correction between studies. No obvious superiority of one technique over the others was found in astigmatic correction. [J Refract Surg. 2019;35(11):690-698.].