MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2019.06.010

Медицинская библиотека · Journal of cataract and refractive surgery · 2019

Tomographic analysis of anterior and posterior surgically induced astigmatism after 2.2 mm temporal clear corneal incisions in femtosecond laser-assisted cataract surgery.

Kohnen Thomas, Löffler Franziska, Herzog Michael, Petermann Kerstin, Böhm Myriam

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate surgically induced astigmatism (SIA) of temporal clear corneal incisions (CCIs) on anterior and posterior corneal curvature after femtosecond laser-assisted cataract surgery (FLACS) using Scheimpflug tomographic measurements.

SETTING

Department of Ophthalmology, Goethe University, Frankfurt am Main, Germany.

DESIGN

Prospective interventional case series.

METHODS

This study enrolled patients who underwent FLACS from June 2013 to July 2014. All eyes were measured with a Pentacam HR preoperatively and at 1 month and 3 months postoperatively, had preoperative total corneal refractive power (TCRP) astigmatism (CATCRP) of 0.50 diopters (D) or less, and received a temporal 2.2 mm incision at 0 degrees and 180 degrees. Vector analysis, using the Holladay-Cravy-Koch formula and the Alpins method, determined astigmatic changes in anterior corneal astigmatism (CAant), posterior corneal astigmatism (CApost), and CATCRP. Student t and Wilcoxon tests were performed. A P value less than 0.05 was considered statistically significant.

RESULTS

This study comprised 53 eyes of 38 patients. At 3 months postoperatively, the CAant, CApost, and CATCRP were significantly higher compared with the preoperative values (P = .015, P = .007, P = .008, respectively); however, CApost and CATCRP were significantly lower compared with the limit of 0.50 D (P < .001, P = .01, respectively), whereas CAant was not (P = .11). The mean SIA of CAant, CApost, and CATCRP was 0.25 D ± 0.15 (SD), 0.16 ± 0.11 D, and 0.28 ± 0.17 D, respectively. The angle of error was high (-1.98 ± 52.95 degrees, 1.64 ± 51.27 degrees, and -1.72 ± 48.79 degrees, respectively).

CONCLUSION

Femtosecond laser temporal CCIs induce minimal astigmatism in CAant, CApost, and CATCRP, but can be evaluated statistically as astigmatically neutral.

Для цитирования: Kohnen Thomas, Löffler Franziska, Herzog Michael, Petermann Kerstin, Böhm Myriam. Tomographic analysis of anterior and posterior surgically induced astigmatism after 2.2 mm temporal clear corneal incisions in femtosecond laser-assisted cataract surgery.. Journal of cataract and refractive surgery. 2019. DOI: 10.1016/j.jcrs.2019.06.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.