MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2019.06.013

Медицинская библиотека · Journal of cataract and refractive surgery · 2019

Comparison of toric intraocular lens alignment error with different toric markers.

Lipsky Lior, Barrett Graham

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the error in intraocular lens (IOL) toric alignment of 2 toric markers.

SETTING

Sir Charles Gairdner Hospital, Perth, Western Australia, Australia.

DESIGN

Retrospective case series.

METHODS

Two consecutive groups of patients had cataract surgery with implantation of an AcrySof SN6A toric IOL (versions T2-T8) by the same surgeon at 2 public hospitals. The only difference in the toric alignment method between the groups was the toric maker used (Group 1: Barrett dual axis toric marker; Group 2: Mendez gauge). A mobile phone application (toriCAM) was used in both groups to determine the reference meridian. The primary outcome measure was the error in toric IOL alignment in degrees at 1 month. The secondary outcome measure was the percentage of eyes achieving a manifest refraction astigmatism within ±0.50 diopter (D) at 1 month.

RESULTS

Seventy-two eyes of 56 patients were included (Group 1: 36 eyes of 35 patients; Group 2: 36 eyes of 25 patients). The mean absolute toric alignment error (intended versus achieved axis of alignment) was 4.0 degrees ± 2.9 (SD) in Group 1 and 8.4 ± 6.5 degrees in Group 2 (P = .0015). Twenty-nine eyes (80.6%) in Group 1 and 21 eyes (53.8%) in Group 2 achieved a manifest refractive astigmatism of 0.50 D or less (P < .05).

CONCLUSION

Toric IOL alignment using the mobile phone application was more accurate with the Barrett dual axis toric marker than with the commonly used Mendez gauge, with a significantly higher percentage of eyes achieving a manifest refraction astigmatism within ±0.50 D.

Для цитирования: Lipsky Lior, Barrett Graham. Comparison of toric intraocular lens alignment error with different toric markers.. Journal of cataract and refractive surgery. 2019. DOI: 10.1016/j.jcrs.2019.06.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.