Combined application of isotropic three-dimensional fast spin echo (3D-FSE-Cube) with 2-point Dixon fat/water separation (FLEX) and 3D-FSE-cube in MR dacryocystography.

Liu Ping, Wang Qiuxia, Peng Chengdong, Luo Ban, Zhang Jing

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

: To evaluate the image quality of magnetic resonance dacryocystography (MRD) using three-dimesional fast spin-echo -Cube (3D-FSE-Cube) and 3D-FSE-Cube-Flex sequences to examine the lacrimal drainage system (LDS).

METHODS

: 21 healthy volunteers underwent 3D-FSE-Cube and 3D-FSE-Cube-Flex MRD after topical administration of compound sodium chloride eye drops. Two radiologists assessed LDS images in a blinded fashion. The signal-to-noise ratio of fluid-filling and the contrast-to-noise ratio of fluid-turbinate were compared between the two sequences. Overall image quality, sharpness, artefacts, visualization of anatomical structures, and visibility of LDS segments were also compared.

RESULTS

: Overall image quality, visualization of anatomic structures, and artefact were significantly better on 3D-FSE-Cube-Flex MRD (p < 0.001, respectively). when compared to 3D-FSE-Cube. 3D-FSE-Cube showed lower fluid-filling signal-to-noise ratio and fluid-inferior turbinate CNR (all p < 0.001). In comparison with 3D-FSE-Cube-Flex, 3D-FSE-Cube produced superior visibility of the upper drainage segments (superior canaliculi, p = 0.003; common canaliculus, p = 0.033; inferior canaliculi, p < 0.001), but inferior in lower-LDS visibility (lacrimal sac, p = 0.001; nasolacrimal duct, p < 0.001). There was no difference in the total number of segments visualized per LDS between the two sequences (p = 0.068).

CONCLUSIONS

: 3D-FSE-Cube-Flex demonstrated superior image quality and visibility of the lower LDS segments. 3D-FSE-Cube showed an advantage in visualizing the upper LDS segments. The combination of these sequences can improve LDS visibility.

ADVANCES IN KNOWLEDGE:: 3D-FSE-Cube-Flex provides robust water & fat separation and mitigates lower LDS-associated inhomogeneity artefacts. 3D-FSE-Cube shows optimal upper LDS visualization. The combined application of these sequences is a non-invasive and effective method for assessing LDS disease.

Для цитирования: Liu Ping, Wang Qiuxia, Peng Chengdong, Luo Ban, Zhang Jing. Combined application of isotropic three-dimensional fast spin echo (3D-FSE-Cube) with 2-point Dixon fat/water separation (FLEX) and 3D-FSE-cube in MR dacryocystography.. The British journal of radiology. 2018. DOI: 10.1259/bjr.20180157.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.