m+Medelevator.RU
← Поиск публикаций
Bulletin of the World Health Organization · 2013

External quality assessment of Giemsa-stained blood film microscopy for the diagnosis of malaria and sleeping sickness in the Democratic Republic of the Congo.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mukadi Pierre, Gillet Philippe, Lukuka Albert, Atua Benjamin, Sheshe Nicole, Kanza Albert, Mayunda Jean Bosco, Mongita Briston, Senga Raphaël, Ngoyi John, Muyembe Jean-Jacques, Jacobs Jan, Lejon Veerle

Аннотация

OBJECTIVE: To report the findings of a second external quality assessment of Giemsa-stained blood film microscopy in the Democratic Republic of the Congo, performed one year after the first.

METHODS: A panel of four slides was delivered to diagnostic laboratories in all provinces of the country. The slides contained: (i) Plasmodium falciparum gametocytes; (ii) P. falciparum trophozoites (reference density: 113,530 per µl); (iii) Trypanosoma brucei subspecies; and (iv) no parasites.

FINDINGS: Of 356 laboratories contacted, 277 (77.8%) responded. Overall, 35.0% of the laboratories reported all four slides correctly but 14.1% reported correct results for 1 or 0 slides. Major errors included not diagnosing trypanosomiasis (50.4%), not recognizing P. falciparum gametocytes (17.5%) and diagnosing malaria from the slide with no parasites (19.0%). The frequency of serious errors in assessing parasite density and in reporting false-positive results was lower than in the previous external quality assessment: 17.2% and 52.3%, respectively, (P < 0.001) for parasite density and 19.0% and 33.3%, respectively, (P < 0.001) for false-positive results. Laboratories that participated in the previous quality assessment performed better than first-time participants and laboratories in provinces with a high number of sleeping sickness cases recognized trypanosomes more frequently (57.0% versus 31.2%, P < 0.001). Malaria rapid diagnostic tests were used by 44.3% of laboratories, almost double the proportion observed in the previous quality assessment.

CONCLUSION: The overall quality of blood film microscopy was poor but was improved by participation in external quality assessments. The failure to recognize trypanosomes in a country where sleeping sickness is endemic is a concern.