MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2471/blt.12.112706

Медицинская библиотека · Bulletin of the World Health Organization · 2013

External quality assessment of Giemsa-stained blood film microscopy for the diagnosis of malaria and sleeping sickness in the Democratic Republic of the Congo.

Mukadi Pierre, Gillet Philippe, Lukuka Albert, Atua Benjamin, Sheshe Nicole, Kanza Albert, Mayunda Jean Bosco, Mongita Briston, Senga Raphaël, Ngoyi John, Muyembe Jean-Jacques, Jacobs Jan, Lejon Veerle

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To report the findings of a second external quality assessment of Giemsa-stained blood film microscopy in the Democratic Republic of the Congo, performed one year after the first.

METHODS

A panel of four slides was delivered to diagnostic laboratories in all provinces of the country. The slides contained: (i) Plasmodium falciparum gametocytes; (ii) P. falciparum trophozoites (reference density: 113,530 per µl); (iii) Trypanosoma brucei subspecies; and (iv) no parasites.

FINDINGS: Of 356 laboratories contacted, 277 (77.8%) responded. Overall, 35.0% of the laboratories reported all four slides correctly but 14.1% reported correct results for 1 or 0 slides. Major errors included not diagnosing trypanosomiasis (50.4%), not recognizing P. falciparum gametocytes (17.5%) and diagnosing malaria from the slide with no parasites (19.0%). The frequency of serious errors in assessing parasite density and in reporting false-positive results was lower than in the previous external quality assessment: 17.2% and 52.3%, respectively, (P < 0.001) for parasite density and 19.0% and 33.3%, respectively, (P < 0.001) for false-positive results. Laboratories that participated in the previous quality assessment performed better than first-time participants and laboratories in provinces with a high number of sleeping sickness cases recognized trypanosomes more frequently (57.0% versus 31.2%, P < 0.001). Malaria rapid diagnostic tests were used by 44.3% of laboratories, almost double the proportion observed in the previous quality assessment.

CONCLUSION

The overall quality of blood film microscopy was poor but was improved by participation in external quality assessments. The failure to recognize trypanosomes in a country where sleeping sickness is endemic is a concern.

Для цитирования: Mukadi Pierre, Gillet Philippe, Lukuka Albert, Atua Benjamin, Sheshe Nicole, Kanza Albert, Mayunda Jean Bosco, Mongita Briston, Senga Raphaël, Ngoyi John, Muyembe Jean-Jacques, Jacobs Jan, Lejon Veerle. External quality assessment of Giemsa-stained blood film microscopy for the diagnosis of malaria and sleeping sickness in the Democratic Republic of the Congo.. Bulletin of the World Health Organization. 2013. DOI: 10.2471/blt.12.112706.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.