PURPOSE: To identify viral pathogens in patients with secondary glaucoma associated with anterior segment uveitis and compare metagenomic deep sequencing (MDS) with enzyme-linked immunosorbent assay (ELISA) combined with Witmer-Desmonts coefficient (WDC) evaluation and real-time quantitative polymerase chain reaction (qPCR) on investigating pathogens in aqueous humor.

METHODS

Aqueous humor from 31 patients, including 22 Posner-Schlossman Syndrome and 9 other anterior uveitis, was assessed pathogens by ELISA combined with WDC evaluation, virus deoxyribonucleic acid (DNA) detection by real-time qPCR and MDS.

RESULTS

Viral pathogens (HCMV or VZV or RV) were detected in 19 out of 31 eyes (61.3%) by real-time qPCR or WDC evaluation. MDS revealed the presence of HCMV DNA sequences in three PSS patients.

CONCLUSION

Virus is an important pathogen in secondary glaucoma associated with anterior segment uveitis. MDS is a potential etiologic diagnosis tool to seek intraocular viral pathogens for secondary glaucoma associated anterior segment uveitis.

Для цитирования: Wang Li, Wang Zhujian, Ma Jinmin, Li Qiongfang, Chen Xueli, Chen Yuhong, Sun Xinghuai. Comparison of Intraocular Antibody Measurement, Quantitative Pathogen PCR, and Metagenomic Deep Sequencing of Aqueous Humor in Secondary Glaucoma Associated with Anterior Segment Uveitis.. Ocular immunology and inflammation. 2020. DOI: 10.1080/09273948.2020.1776883.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.