Blunt splenic trauma: can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

Poletti Pierre-Alexandre, Becker Christoph D, Arditi Daniel, Terraz Sylvain, Buchs Nicolas, Shanmuganathan Kathirkamanathan, Platon Alexandra

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization.

METHODS

Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48-72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board.

RESULTS

CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively.

CONCLUSION

Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT.

Для цитирования: Poletti Pierre-Alexandre, Becker Christoph D, Arditi Daniel, Terraz Sylvain, Buchs Nicolas, Shanmuganathan Kathirkamanathan, Platon Alexandra. Blunt splenic trauma: can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?. European journal of radiology. 2013. DOI: 10.1016/j.ejrad.2013.05.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.