MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cyt.13228

Медицинская библиотека · Cytopathology : official journal of the British Society for Clinical Cytology · 2023

Quality of cell blocks prepared from residual pleural effusion and bronchial washing samples for immunocytochemistry.

Harabajsa Suzana, Milutin Lucija, Breški Anita, Ražnjević Katarina, Šimić Vesna, Branica Božica Vrabec, Smojver-Ježek Silvana

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Cell blocks (CBs) enable the long-term preservation of cytological samples. The aim of this study was to analyse the quality of CBs prepared from leftover fluid from lung adenocarcinoma pleural effusion samples and residual bronchial washing sediment for immunocytochemistry.

METHODS

The residual part of 455 lung adenocarcinoma pleural effusion samples and sediment from 384 bronchial washing samples were used to prepare CBs following the agarose method. The quality of CBs was evaluated based on the quantity of malignant cells in haematoxylin and eosin-stained slides and interpreted as optimal or insufficient for immunocytochemistry. Immunocytochemistry on CBs was performed using the Dako EnVision™ FLEX detection visualisation system. The CB results for TTF-1, ALK, and PD-L1 immunocytochemistry were compared with the corresponding cytological smears.

RESULTS

Among all CBs, 202 (44.4%) from leftover pleural effusion fluid and 85 (22.1%) from residual bronchial washing sediment had an optimal number of lung adenocarcinoma cells. Eight pleural effusion CBs were stained for TTF-1. Four pleural effusion and two bronchial washing CBs were stained for ALK and PD-L1. All tested pleural effusion CBs were confirmed positive for TTF-1 and negative for ALK. The PD-L1 tumour proportion score (TPS) was ≥ 50% in two pleural effusions. ALK was confirmed negative in bronchial washing CBs. One bronchial washing CB was interpreted as PD-L1-negative while the corresponding smear was positive (TPS ≥1%; 2%).

CONCLUSION

The CB results of TTF-1, ALK, and PD-L1 corresponded to the findings for the smears. The inclusion of CBs prepared from leftover fluid from pleural effusion samples and residual bronchial washing sediment in routine cytological practice could provide a source of high-quality material for immunocytochemistry in addition to smears and cytospins.

Для цитирования: Harabajsa Suzana, Milutin Lucija, Breški Anita, Ražnjević Katarina, Šimić Vesna, Branica Božica Vrabec, Smojver-Ježek Silvana. Quality of cell blocks prepared from residual pleural effusion and bronchial washing samples for immunocytochemistry.. Cytopathology : official journal of the British Society for Clinical Cytology. 2023. DOI: 10.1111/cyt.13228.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.