MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10815-024-03293-5

Медицинская библиотека · Journal of assisted reproduction and genetics · 2024

Dual trigger versus human chorionic gonadotropin trigger for blastocyst quality and cumulative live birth.

He Zining, Liu Yalong, Huang Ning, Liu Xintong, Zeng Lin, Lian Ying, Li Rong, Chi Hongbin

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the difference in the number of euploid blastocysts and cumulative live birth rate (LBR) between dual and human chorionic gonadotropin (hCG) triggers in poor and normal ovarian responders undergoing preimplantation genetic testing (PGT) cycles.

METHODS

This retrospective cohort study was enrolled from July 2018 to December 2021 and followed up until June 2024 at a single reproductive medical center. Overall, 1040 in vitro fertilization (IVF)-PGT and 784 frozen-thawed embryo transfer (FET) cycles were assessed. Dual (triptorelin acetate 0.2 mg and recombinant hCG [rhCG] 250 µg) or hCG (rhCG 250 µg) trigger was used for oocyte maturation in the gonadotropin-releasing hormone antagonist protocol and PGT cycles. We assessed the embryo outcomes and FET cumulative pregnancy outcomes.

RESULTS

The number of oocytes retrieved (10.17 ± 5.22 vs 10.27 ± 5.14, P = 0.789), MII oocytes (8.24 ± 4.26 vs 8.28 ± 4.05, P = 0.888), blastocysts (2.16 ± 1.50 vs 2.12 ± 1.49, P = 0.729), euploid blastocysts (1.06 ± 1.14 vs 1.09 ± 1.23, P = 0.726), and the rate of cumulative LBR (24.9% vs 24.9%, P = 1.000) in the dual trigger group were comparable with those in the hCG group. The trigger method was not correlated with higher LBR based on logistic regression analysis (odds ratio[OR] = 1.040 [0.778-1.392], P = 0.790).

CONCLUSION

For poor and normal ovarian responders, the dual trigger, compared with the hCG trigger, did not improve the PGT embryo outcomes and FET cumulative pregnancy outcomes.

Для цитирования: He Zining, Liu Yalong, Huang Ning, Liu Xintong, Zeng Lin, Lian Ying, Li Rong, Chi Hongbin. Dual trigger versus human chorionic gonadotropin trigger for blastocyst quality and cumulative live birth.. Journal of assisted reproduction and genetics. 2024. DOI: 10.1007/s10815-024-03293-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.