[Analysis of changes of anterior chamber depth after IOL implantation].

Tang Ping, Zhang Hui-ying, Wang Hong

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the changes of the anterior chamber depth (ACD) and the related factors after cataract surgery with IOL implantation in order to achieve the intended postoperative refraction.

METHODS

Preoperative and postoperative ACD were examined in 117 patients (177 eyes) who underwent cataract surgery (phacoemulsification and posterior chamber IOL implantation). Correlations between changes of ACD and the axial lengths of the eyes, K-readings and IOL A-constants were assessed. Patients were followed-up for 3 to 24 months.

RESULTS

(1) There was significant difference between preoperative ACD (3.19 +/- 0.39) mm and postoperative ACD (4.22 +/- 0.65) mm (P = 0.000). (2) The mean postoperative ACD change was (1.03 +/- 0.61) mm. The correlations between the ACD changes and the axial lengths of the eye and K-readings were statistically significant. (r = 0.866, r = 0.946, P = 0.001). (3) There was significant difference between preoperative ACD and postoperative ACD in the three different A-constants groups (118.9, 118.0 and 118.4) (P = 0.004, 0.001 and 0.001). There was significant difference between ACD changes in patients with A-constant 118.9 and that of 118.0 or 118.4 (P = 0.007, P = 0.01). There was no significant difference between ACD changes in patients with A-constant 118.0 and that of 118.4 (P = 0.957).

CONCLUSION

Cataract surgery deepened anterior chambers at varying degrees, depending on the axial lengths of the eye, K-readings and the IOL A-constants. ACD changes and relevant factors should be considered in studying the accuracy of IOL refraction formula and in adjusting the calculated data.

Для цитирования: Tang Ping, Zhang Hui-ying, Wang Hong. [Analysis of changes of anterior chamber depth after IOL implantation].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.