Impact of decentration of astigmatic intra-ocular lenses on the residual refraction after cataract surgery.

Langenbucher Achim, Reese Sven, Seitz Berthold

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study is to assess the impact of decentration of astigmatic intra-ocular lenses on the residual refraction after cataract surgery, using a computing scheme with 5 x 5 system matrices.

METHODS

Based on the definition of an optical system in the paraxial Gaussian space containing astigmatic surfaces without restrictions to coaxiality, we derived a method (using 5 x 5 refraction and translation matrices) for calculating the residual refraction and the compensating prism in the spectacle plane after decentred implantation of thin and thick astigmatic intra-ocular lenses. The 'optical system eye' may contain astigmatic refractive surfaces with their axes at random.

RESULTS

The capabilities of this computing scheme are demonstrated with two examples. In example 1 we calculate the residual refraction of a decentred 'thin astigmatic lens' for compensation of corneal astigmatism to achieve a spherical target refraction. In example 2 we compute the residual refraction after implantation of a 'thick astigmatic lens', where the spherical and cylindrical power as well as the implantation axis of the lens do not fully match the pre-operative recommendations and the lens is decentred relative to the optical axis. For both examples, we derive the residual prismatic effect in the spectacle plane and the lateral displacement of a ray exiting the spectacle correction when starting coaxially at the retina.

CONCLUSIONS

We have presented an en bloc matrix-based strategy for the calculation of the residual spherocylindrical refraction at the spectacle plane after implantation of a decentred thin or thick astigmatic intra-ocular lens without restrictions to coaxiality. The resulting system matrix is written as a product of 5 x 5 refraction and translation matrices.

Для цитирования: Langenbucher Achim, Reese Sven, Seitz Berthold. Impact of decentration of astigmatic intra-ocular lenses on the residual refraction after cataract surgery.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2005. DOI: 10.1111/j.1475-1313.2005.00335.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.