MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2005.02.039

Медицинская библиотека · Journal of cataract and refractive surgery · 2005

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation.

Rodríguez-Galietero Antonio, Montés-Micó Robert, Muñoz Gonzalo, Albarrán-Diego Cesar

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare contrast sensitivity and color vision in patients in whom blue-light filtering and non-yellow-tinted intraocular lenses (IOLs) were implanted.

SETTING

Refractive Surgery Unit, Hospital NISA Valencia al Mar, Valencia, Spain.

METHODS

Forty eyes of 20 patients were enrolled in a blue-light filtering fellow-eye control study; patients were implanted with a yellow-tinted IOL (AcrySof Natural, Alcon) in 1 eye and a non-yellow-tinted IOL (AcrySof SA60AT, Alcon) in the fellow eye after cataract surgery. Three months postoperatively, monocular contrast sensitivity function was measured with the CSV 1000-E contrast sensitivity chart at distance and the color discrimination with the Farnsworth-Munsell 100 Hue test.

RESULTS

Eyes implanted with blue-light filtering IOLs showed similar contrast sensitivity to that in fellow eyes implanted with non-yellow-tinted IOLs (P>.1). Both types of IOLs showed normal contrast sensitivity values (normalized log-contrast sensitivity about 1.0). There were no statistically significant differences in chromatic discrimination between the 2 types of IOLs (P = .56).

CONCLUSION

The use of blue-light filtering IOLs is more advisable because they are capable of protecting the retina against ultraviolet light without disturbance of contrast sensitivity and chromatic vision, which produces subjective impairment in visual function.

Для цитирования: Rodríguez-Galietero Antonio, Montés-Micó Robert, Muñoz Gonzalo, Albarrán-Diego Cesar. Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation.. Journal of cataract and refractive surgery. 2005. DOI: 10.1016/j.jcrs.2005.02.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.