DOI 10.1016/j.jcrs.2004.06.021
Comparison of wavefront aberration after cataract surgery with acrylic intraocular lens implantation.
Аннотация
PURPOSE: To compare aberration changes in pseudophakic eyes with 3 types of acrylic intraocular lenses (IOLs) and in normal phakic eyes.
SETTING
Department of Ophthalmology, Asan Medical Center, Seoul, Korea.
METHODS
This single-center prospective study comprised 51 cataract patients who had cataract surgery and 12 phakic eyes. Fourteen eyes received an AcrySof MA60BM (Alcon), 18 eyes received a Sensar AR40 (AMO), and 19 eyes, a Corneal ACR6D (Corneal Laboratoire). One month after cataract surgery, aberrations in the eyes were measured using a Hartmann-Shack-type aberrometer. The same measurements were done in the 12 age-matched normal phakic eyes. Individual Zernike polynomials and the root-mean-square (RMS) 3rd- and 4th-order aberrations in the 2 groups were compared. The total RMS value was also compared.
RESULTS
The RMS value of the 3rd- and 4th-order aberrations did not differ significantly between groups, nor did the total RMS value. In all IOL groups, an individual Zernike coefficient (C3(3), triangular astigmatism with base on the y-axis) was significantly different than that in the normal phakic group.
CONCLUSION
There was no statistically significant difference in overall higher-order aberrations between normal eyes and eyes implanted with 3 types of acrylic IOLs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.