MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4321/s0365-66912005000200004

Медицинская библиотека · Archivos de la Sociedad Espanola de Oftalmologia · 2005

[Spherical aberration influence in visual function after cataract surgery: prospective randomized trial].

Martínez Palmer A, Palacín Miranda B, Castilla Céspedes M, Comas Serrano M, Puntí Badosa A

Клиническое исследованиеСравнительное исследованиеАннотация на английскомСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: We compare the contrast sensitivity and visual acuity obtained with an anterior surface modified prolate intraocular lens (Tecnis Z9000) with the contrast sensitivity and visual acuity obtained with a standard acrylic foldable intraocular lens (Acrysof SA60 AT).

METHODS

In this prospective trial, 64 patients presenting for cataract surgery were randomized to receive in both eyes either the Tecnis Z9000 intraocular lens or the the Acrysof SA60AT intraocular lens: 32 Tecnis Z9000 and 32 Acrysof SA60AT. Visual acuity and contrast sensitivity were monocular and binocularly tested in all of them preoperatively and three months after surgery.

RESULTS

The Tecnis Z9000 intraocular lens provided statistically significantly better monocular (Tecnis group: 0.85; Acrysof group: 0.78; p < 0.01) and binocular (Tecnis group: 0.95; Acrysof group: 0.86; p < 0.02) visual acuity. The contrast sensitivity mean was also greater in Tecnis group in monocular and binocular conditions, but without statistical signification.

CONCLUSION

Visual acuity and contrast sensitivity after cataract surgery improved in both groups. But monocular and binocular visual acuity was statistically significantly better only in Tecnis group. The contrast sensitivity mean values were greater in Tecnis group but without statistically significant differences.

Для цитирования: Martínez Palmer A, Palacín Miranda B, Castilla Céspedes M, Comas Serrano M, Puntí Badosa A. [Spherical aberration influence in visual function after cataract surgery: prospective randomized trial].. Archivos de la Sociedad Espanola de Oftalmologia. 2005. DOI: 10.4321/s0365-66912005000200004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.