MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2004.03.020

Медицинская библиотека · American journal of ophthalmology · 2004

Effect of cataract extraction on frequency doubling technology perimetry.

Kook Michael S, Yang Sung Jae, Kim Suhyun, Chung Jiyong, Kim Soon-Tae, Tchah Hungwon

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the effect of cataract extraction on the results of frequency doubling technology (FDT) perimetry in healthy subjects.

DESIGN

Single-center, prospective, case series.

METHODS

We performed FDT threshold C20-1 and Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast programs within 1 month before and 2 months after phacoemulsification in 52 consecutive nonglaucomatous patients. Global indexes, including mean deviation and mean sensitivity of FDT and mean deviation of SITA-fast, were compared before and after cataract surgery. Mean sensitivity of FDT at various visual field grid locations was also compared before and after cataract surgery, as were localized indexes of both FDT and SITA-fast.

RESULTS

Mean deviation improved after cataract surgery in both FDT threshold (from -7.09 dB--2.16 dB) and SITA-fast program (from -6.14 dB--2.87 dB). The mean sensitivity at 17 grid locations when the FDT threshold program was used significantly improved postoperatively (from 19.6 dB-26.13 dB). Postoperative improvements in mean sensitivity were also significant at all different sectors, but there were no significant differences of improvement among them. Postoperative pattern standard deviations from FDT and SITA-fast did not differ significantly from their preoperative values.

CONCLUSIONS

Cataracts induced a generalized reduction of sensitivity in FDT threshold as well as SITA-fast perimetry. Cataract removal did not change pattern standard deviation of FDT or of SITA-fast. Caution should be taken when interpreting the results of FDT perimetry in the eyes with cataract.

Для цитирования: Kook Michael S, Yang Sung Jae, Kim Suhyun, Chung Jiyong, Kim Soon-Tae, Tchah Hungwon. Effect of cataract extraction on frequency doubling technology perimetry.. American journal of ophthalmology. 2004. DOI: 10.1016/j.ajo.2004.03.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.