Journal of cataract and refractive surgery · 2004

Relationship between anterior capsule contraction and posterior capsule opacification after cataract surgery in patients with diabetes mellitus.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hayashi Yoshie, Kato Satoshi, Fukushima Harumi, Numaga Jiro, Kaiya Tadayoshi, Tamaki Yasuhiro, Oshika Tetsuro

Аннотация

PURPOSE: To prospectively assess the relationship between contraction of the anterior capsule opening and posterior capsule opacification (PCO) after cataract surgery in patients with diabetes mellitus.

SETTING: Department of Ophthalmology, University of Tokyo School of Medicine, Tokyo, Kaiya Eye Clinic, Hamamatsu, and Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaragi, Japan.

METHODS: This study comprised 45 patients (45 eyes) with diabetes mellitus who had cataract surgery. In all eyes, the anterior capsule opening area and degree of PCO were determined by diaphanoscopy using an anterior eye segment analysis system (EAS-100, Nidek, Inc.) 1 day and 1 year postoperatively.

RESULTS: There was no correlation between the size of the anterior capsule opening area 1 day after surgery and the degree of PCO 1 year after surgery (Pearson correlation coefficient [r] = 0.041; P =.79). The percentage reduction in the anterior capsule opening area from 1 day to 1 year after surgery did not correlate with the degree of PCO 1 year after surgery (r = -0.08; P =.60).

CONCLUSION: Contraction of the anterior capsule opening and PCO after cataract surgery cannot be explained by a common mechanism.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты