MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics11040677

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2021

Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial.

Formánek Martin, Dedek Vladimír, Koláček Michal, Havel Martin, Zeleník Karol, Komínek Pavel

СтатьяПеревод пока не подготовлен

Аннотация

Background

Minimally invasive parathyroidectomy is the preferred treatment for primary hyperparathyroidism. Despite relatively accurate preoperative information, minimally invasive parathyroidectomy can be challenging, especially in the case of small and ectopic adenomas. Radio guidance aids in both in vivo identification and ex vivo confirmation of adenoma. In vivo accuracy is currently not satisfactory. The present study evaluated whether a beneficial effect (increased sensitivity, specificity, accuracy) is obtained with individualised timing of minimally invasive radio-guided parathyroidectomy (MIRGP) using preoperative multi-phase 99mTc-MIBI single photon emission computed tomography (SPECT)/computed tomography (CT).

Methods

This randomised clinical trial was conducted from May 2016 to January 2020 in a tertiary referral hospital. Adult patients with primary hyperparathyroidism sent for 99mTc-MIBI SPECT/CT were included consecutively and randomly assigned to conventional (dual-phase) SPECT/CT and conventional MIRGP (group I) or multi-phase SPECT/CT and individualised MIRGP (group II). One hundred of 106 eligible patients were included, and 83 patients underwent complete intervention.

Results

A total of 47 patients in group I and 35 patients in group II were analysed. Group II had a shorter operating time (p = 0.003). The in vivo sensitivity and accuracy of radio guidance was 85.1% in group I and 100% in group II (p = 0.046), and 90.4% in group I and 100% in group II (p = 0.021), respectively. We found no difference in the in vivo specificity and ex vivo parameters between groups.

Conclusion

Individualised timing increased the in vivo sensitivity and accuracy of radio guidance and reduced operating time, as some parathyroid adenomas rapidly wash out the radionuclide.

Для цитирования: Formánek Martin, Dedek Vladimír, Koláček Michal, Havel Martin, Zeleník Karol, Komínek Pavel. Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial.. Diagnostics (Basel, Switzerland). 2021. DOI: 10.3390/diagnostics11040677.