Implementation of a 4-dimensional computed tomography protocol for parathyroid adenoma localization.

Jategaonkar Ameya A, Lerner David K, Cooke Peter, Kirke Diana, Genden Eric M, Trosman Samuel J

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To present the results of our implementation of a four-dimensional computed tomography- (4DCT) based parathyroid localization protocol for primary hyperparathyroidism at a safety net hospital.

METHODS

We performed a retrospective review of all patients who underwent parathyroidectomy for primary hyperparathyroidism at Elmhurst Hospital Center from June 2016 - September 2019. Patients treated prior to the implementation of 4DCT during October 2018 served as historical controls for comparison. Imaging-related costs and hospital charges were obtained from the Radiology Department for each patient.

RESULTS

Forty-two patients underwent parathyroid surgery during the study period. Twenty patients had undergone 4DCT while 22 had nuclear medicine studies with or without ultrasonography. The sensitivity and specificity of 4DCT was 90.4% and 100% respectively, compared to 63% and 93.7% for nuclear imaging studies and 41% and 95% for ultrasound. The mean number of glands explored was significantly less in the 4DCT group, 1.8 ± 1.19 versus 2.77 ± 1.26 (p = 0.01). There was no increase in infrastructure or personnel costs associated with 4DCT implementation.

CONCLUSIONS

4DCT represents an increasingly common imaging modality for pre-operative parathyroid localization. Here we demonstrate that 4DCT is associated with a reduction in the number of glands explored and enables minimally invasive parathyroid surgery. 4DCT is a cost-effective and clinically sound localization study for parathyroid localization in an urban safety-net hospital.

Для цитирования: Jategaonkar Ameya A, Lerner David K, Cooke Peter, Kirke Diana, Genden Eric M, Trosman Samuel J. Implementation of a 4-dimensional computed tomography protocol for parathyroid adenoma localization.. American journal of otolaryngology. 2021. DOI: 10.1016/j.amjoto.2021.102907.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.