MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11547-019-01020-0

Медицинская библиотека · La Radiologia medica · 2019

Safety and efficacy of transcatheter embolization in patients with massive hemoptysis due to intercostal pulmonary venous shunts.

Fu Zhigang, Liang Yonghui, Zhao Wengjiang, Tian Jie, Cai Fei, Zhang Xiaolin

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Bronchial hemoptysis induced by intercostal pulmonary venous shunt (IPVS) is clinically rare. Pulmonary lesions on pleural surface may facilitate opening of vascular network. This retrospective study investigated safety and efficacy of embolization agents with small-particle embolization treating patients with massive hemoptysis due to IPVS.

METHODS

Patients with massive hemoptysis (n = 207) underwent computed tomography angiography of bronchial artery. Depending on results, selective or superselective digital subtraction angiography and embolization were performed. Polyvinyl alcohol (300-500 μm), or microcoils combined with polyvinyl alcohol, was utilized according to IPVS volume. Vital signs of each patient were closely monitored.

RESULTS

Of 207 patients with massive hemoptysis, 24 (11.6%) had IPVS syndrome. Patients with IPVS had concomitant bronchiectasis (54.2%), followed by tuberculosis (25.0%). Embolizations were performed in 39 culprit intercostal arteries; 37 (94.9%) of these were successfully embolized. Of the latter, 30 and 7 arteries were embolized, respectively, by polyvinyl alcohol alone or polyvinyl alcohol particles combined with microcoils. Embolization failed in one case because the agents could not enter the intercostal artery. If artery dissection occurred during procedure, microcoils were utilized to embolize the main artery. No skin necrosis, spinal artery embolization, or death occurred. Immediate clinical success was achieved in 22 patients (91.7%) after embolization. Two patients (8.3%) experienced recurrence of hemoptysis. Only four patients experienced mild hemoptysis during the 24-month follow-up with the efficiency of 75.0%.

CONCLUSIONS

Intercostal artery embolization with 300-500 μm alone or combined with microcoils is a safe and effective procedure in patients with IPVS-induced bronchial hemoptysis.

Для цитирования: Fu Zhigang, Liang Yonghui, Zhao Wengjiang, Tian Jie, Cai Fei, Zhang Xiaolin. Safety and efficacy of transcatheter embolization in patients with massive hemoptysis due to intercostal pulmonary venous shunts.. La Radiologia medica. 2019. DOI: 10.1007/s11547-019-01020-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.