Feasibility of computerized adventitious respiratory sounds to assess the effects of airway clearance techniques in patients with bronchiectasis.

Herrero-Cortina Beatriz, Oliveira Ana, Polverino Eva, Gómez-Trullén Eva María, Torres Antoni, Marques Alda

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

Objective

To examine the feasibility of adventitious respiratory sound (ARS) as an outcome measure to assess the effects of airway clearance techniques (ACTs) in outpatients with bronchiectasis.

Methods

ARS were registered pre/post four ACTs sessions. Clinical outcomes included: number of crackles (coarse and fine), number of wheezes (monophonic and polyphonic), wheezes occupation rate (%) and sputum quantity. Feasibility outcomes of ARS included: reasons for exclusion, suitability, safety, equipment and time required, magnitude of change after intervention and sample size estimation.

Results

Seven patients (49.7 ± 20.5 years; FEV1 69.3 ± 15.8% predicted) were included. Recordings from four patients were excluded due to excessive environment noise. All ARS measurements were completed without any adverse events. An electronic stethoscope was acquired and the time spent to complete each assessment was 6 ± 3.5 min. The largest changes were observed for number of expiratory coarse crackles [effect size (95%CI) ES = 0.40 (0.01-0.79)], which correlated moderately with sputum quantity (r = 0.56), and inspiratory monophonic wheezes [ES = 0.61 (0.22-1.00)]. The estimated sample size for a full crossover trial was 46.

Conclusions

ARS is feasible to assess the effects of ACTs in patients with bronchiectasis. Expiratory coarse crackles seem to be the most appropriate ARS parameter, but this finding needs to be confirmed in an adequately powered trial.

Для цитирования: Herrero-Cortina Beatriz, Oliveira Ana, Polverino Eva, Gómez-Trullén Eva María, Torres Antoni, Marques Alda. Feasibility of computerized adventitious respiratory sounds to assess the effects of airway clearance techniques in patients with bronchiectasis.. Physiotherapy theory and practice. 2019. DOI: 10.1080/09593985.2019.1566945.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.