Advanced Reliability of Radiomic Features in Ex Vivo HypersightTM-CBCT Imaging by iCBCT-Acuros Reconstruction.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Siefert Victor, Haag Florian, Bicu Alicia S, Schmidt Ralf, Willam Marvin, Eckl Miriam, Stieler Florian, Ehmann Michael, Buergy Daniel, Fleckenstein Jens, Schoenberg Stefan O, Giordano Frank A, Boda-Heggemann Judit, Froelich Matthias F, Dreher Constantin

Аннотация

BACKGROUND/AIM: High-quality cone-beam CT (CBCT) imaging, such as HyperSight™-CBCT on the ETHOS® O-ring linear accelerator, has significantly improved adaptive radiotherapy by providing high imaging precision. Advanced reconstruction techniques like the iCBCT-Acuros reconstruction mode have the potential to enhance reliability of quantitative image evaluations, especially regarding interpretation of radiomic features. This study evaluated how the iCBCT-Acuros reconstruction mode improves reliability of radiomic features compared to standard iCBCT in HyperSight™-CBCT imaging.

MATERIALS AND METHODS: An ex vivo phantom analysis of 16 fruits and vegetables was conducted with HyperSight™-CBCT using iCBCT and iCBCT-Acuros reconstruction modes. Test-retest reliability was assessed at 0° and 90° rotations, along with inter- and intrareader reliability, inter-reconstruction reproducibility, and interphantom discrimination. A total of 110 radiomic features were extracted with LIFEx software, and reliability was analyzed using concordance and intraclass correlation coefficients. Boruta Random Forest analysis evaluated interphantom discrimination.

RESULTS: Mean test-retest reliability (CCC) was higher for iCBCT-Acuros (0.936±0.137) than iCBCT (0.816±0.199, p<0.0001). "Morphological" features showed the highest reliability for both modes. Interreader and intrareader reliability were significantly higher for iCBCT-Acuros (p<0.0001). Reproducibility was moderate overall (mean 0.832±0.224), with "Morphological" features being most reproducible. Interphantom separability was increased with iCBCT-Acuros.

CONCLUSION: The iCBCT-Acuros reconstruction mode of HyperSight™-CBCT significantly improves radiomic feature reliability compared to iCBCT. These advancements likely extend to other quantitative parameters, enhancing their potential as radiological biomarkers. The iCBCT-Acuros reconstruction enables a significantly more robust imaging analysis, facilitating the integration of advanced quantitative imaging techniques into high-precision radiotherapy.