MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2022.105272

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2022

Experimental determination of the contact pressures produced by a nasal continuous positive airway pressure mask: A case study.

Savoldi Fabio, Svanetti Lorenzo, Tsoi James K H, Gu Min, Paganelli Corrado, Genna Francesco, Lopomo Nicola F

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

A continuous positive airway pressure (CPAP) mask is a respiratory ventilation method used for treating breathing disorders including respiratory failure and obstructive sleep apnoea (OSA). The forces applied by a CPAP mask may affect facial development and lead to pressure ulcers. In an experimental setting, the magnitude and the distribution of the contact pressures developed by a CPAP mask on the face were investigated for providing information aiming at optimizing the design of the device.

MATERIALS AND

METHODS

A nasal CPAP mask with forehead support was placed via its headgear straps on a rigid phantom head and then a controlled load was incrementally applied via a mechanical testing system (5848 Micro Tester, Instron), up to 4 maximum levels of exerted force, namely 5 N, 10 N, 15 N, and 20 N. Real-time pressure mapping was realized by means of sensor matrixes (I-Scan System, Tekscan) applied on the facial surface in four regions (forehead, nasal bridge, zygoma, and maxilla). The data were then transferred on a virtual model created by 3D scans of both the CPAP mask and the phantom head used in the experiments.

RESULTS

At increasing applied force, increases in average contact pressure were present at the zygomatic region (1-8 kPa), nasal bridge (12-14 kPa), and forehead (13-29 kPa), while the maxillary region showed relatively stable values (9 kPa). Despite the overall increase in average contact pressure with increasing applied force, no direct proportionality was present. Contact areas did not show clear increments, despite force may redistribute on a larger area, as sensors did not cover the entire mask perimeter. Peak contact pressure values were somehow affected by pressure concentrations that led to saturation in some areas of the sensors (up to 2% of the sensels).

CONCLUSIONS

The CPAP mask exerts pressures that may be not uniformly distributed on the face of a subject. This information underlines the clinical importance of assessing both the pressure exerted and the areas that are interested by the mask contact, so as to optimise the CPAP masks design for obtaining a good compromise between ventilation performance and reduction of possible side effects on living tissues.

Для цитирования: Savoldi Fabio, Svanetti Lorenzo, Tsoi James K H, Gu Min, Paganelli Corrado, Genna Francesco, Lopomo Nicola F. Experimental determination of the contact pressures produced by a nasal continuous positive airway pressure mask: A case study.. Journal of the mechanical behavior of biomedical materials. 2022. DOI: 10.1016/j.jmbbm.2022.105272.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.