Disparities in oxygen saturation and hypoxic burden levels in obstructive sleep apnoea patient's response to oral appliance treatment.

Park Ji Woon, Almeida Fernanda R

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Oxygen saturation indices show a strong correlation with long-term health outcomes. Nonetheless, evidence on the relationship between reduction in respiratory events and increase in oxygenation levels following oral appliance (OA) treatment is scarce.

OBJECTIVES

To verify the relationship between reduction in the apnoea-hypopnoea index (AHI) and oxygen saturation levels following OA treatment, we have conducted an evaluation of polysomnography (PSG) and clinical parameters associated with the improvement of oxygen desaturation.

METHODS

OSA patients (n = 48) who received an OA and had pre- and post-treatment PSG were classified into three responder groups according to the change in AHI and min O2 post-treatment: responderAHIonly (decrease in AHI of ≥50% but increase in min O2  level of <4% or decrease); responderMinO2only (increase in min O2  level of ≥4% but decrease in AHI <50% or increase) and responderCongruous (decrease in AHI of ≥50% and increase in min O2  level of ≥4%). Various demographic and PSG variables were statistically compared among groups.

RESULTS

There were 26 (54.17%) responderAHIonly , 9 (18.75%) responderMinO2only and 13 (27.08%) responderCongruous . Pre-treatment min O2 was significantly lower in responderMinO2only . A higher pre-treatment min O2  showed a significant correlation with a smaller amount of change in mean O2 (r = -.486) and min O2 (r = -.764) with treatment. Pre-treatment min O2  showed the strongest ability to predict those who would show a ≥4% min O2 increase following treatment.

CONCLUSION

Certain patients do not show sufficient decrease in hypoxaemia in spite of the improvement in AHI. Pre-treatment min O2  should be considered in OA treatment planning regarding its close relation to improvements in oxygenation levels with treatment.

Для цитирования: Park Ji Woon, Almeida Fernanda R. Disparities in oxygen saturation and hypoxic burden levels in obstructive sleep apnoea patient's response to oral appliance treatment.. Journal of oral rehabilitation. 2022. DOI: 10.1111/joor.13316.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.