Elucidation of obstructive sleep apnoea related blood pressure surge using a novel continuous beat-to-beat blood pressure monitoring system.

Kwon Younghoon, Baruch Martin, Stafford Patrick L, Bonner Heather, Cho Yeilim, Mazimba Sula, Logan Jeongok G, Shimbo Daichi, Park Sung-Ha, Lin Gen-Min, Azarbarzin Ali, Calhoun David A, Berry Richard, Carey Robert M

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Obstructive sleep apnoea (OSA) episode related blood pressure (BP) surge may mediate the association of OSA with cardiovascular disease. However, BP is not measured during a clinical sleep study.

METHOD: We tested the feasibility of incorporating the Caretaker physiological monitor, which utilizes a novel continuous beat-to-beat (b-b) BP monitoring technology, into polysomnography (PSG) and aimed to characterize BP surges related to obstructive respiratory events. B-b BP was concurrently collected and merged with PSG data on a posthoc basis. We compared BP surge between mean respiratory (apnoea, hypopnea and desaturation-alone events) and nonrespiratory events (spontaneous or leg movement-related arousals). We examined the association of the degree of oxygen desaturation with BP surge in a given respiratory event combining all events. A total of 17 consecutive patients (12 men, mean 52 years old, nine diagnostic and eight split-night PSGs) undergoing clinically indicated PSG were included after excluding one patient with poor signal quality due to excessive movement.

RESULTS

Caretaker was well tolerated. Mean respiratory BP surge ranged from 5 to 19 mmHg [Median (IQR) = 13.9 (9.5--16.2)]. Mean BP surge between the respiratory and nonrespiratory events was similar [13.8 (4.5) vs. 14.9 (5.3) mmHg, P = 0.13]. Accounting for the count distribution of desaturation/BP surge data pair events, there was a linear correlation between the degree of oxygen desaturation and BP surge (R = 0.57, P < 0.001). In eight patients undergoing split-night sleep studies, the number of BP surge events (≥10 mmHg/h) decreased during continuous positive airway pressure in all but one patient.

CONCLUSION

We demonstrated highly variable OSA-related BP surge patterns using the Caretaker's b-b BP monitoring technology that has the potential to be integrated into sleep studies.

Для цитирования: Kwon Younghoon, Baruch Martin, Stafford Patrick L, Bonner Heather, Cho Yeilim, Mazimba Sula, Logan Jeongok G, Shimbo Daichi, Park Sung-Ha, Lin Gen-Min, Azarbarzin Ali, Calhoun David A, Berry Richard, Carey Robert M. Elucidation of obstructive sleep apnoea related blood pressure surge using a novel continuous beat-to-beat blood pressure monitoring system.. Journal of hypertension. 2022. DOI: 10.1097/hjh.0000000000003041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.