MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/nan.0000000000000595

Медицинская библиотека · Journal of infusion nursing : the official publication of the Infusion Nurses Society · 2025

Ultrasonography-Observed Subcutaneous Edema Immediately After Peripheral Intravenous Catheter Placement Is a Factor in Subsequent Catheter Failure.

Takahashi Toshiaki, Nakagami Gojiro, Murayama Ryoko, Abe Mari, Sanada Hiromi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aimed to examine the effects of subcutaneous tissue edema at the site of peripheral intravenous catheters (PIVCs) on catheter failure.

METHODS

A secondary analysis was conducted based on an interventional study performed in 1 ward of the University of Tokyo Hospital. Participants included patients with PIVCs without ultrasonographic-guided insertion. Ultrasonographic images were obtained immediately after catheter placement was completed to assess for success of catheterization and subcutaneous edema. Catheter failure was defined as a PIVC with incomplete treatment. Other measured variables included nursing skill defined as number of experiences of catheterization, medications, medical history, anatomical site of catheterization, diameter of vein, and depth of the catheterization.

RESULTS

Of the 273 PIVC cases analyzed, 19 (7.0%) had subcutaneous edema immediately after catheter placement, and 79 (28.9%) resulted in catheter failure, 15 (78.9%) of which occurred among patients with subcutaneous edema (P < .01). Subcutaneous edema immediately after catheter placement was significantly associated with catheter failure occurrence (P < .01), with an adjusted hazard ratio of 9.4 (95% confidence interval 4.62-19.44).

CONCLUSION

Subcutaneous edema was identified as a predictor of catheter failure. Ultrasonographic observation of subcutaneous edema at PIVC placement may be effective in preventing catheter failure occurrence.

Для цитирования: Takahashi Toshiaki, Nakagami Gojiro, Murayama Ryoko, Abe Mari, Sanada Hiromi. Ultrasonography-Observed Subcutaneous Edema Immediately After Peripheral Intravenous Catheter Placement Is a Factor in Subsequent Catheter Failure.. Journal of infusion nursing : the official publication of the Infusion Nurses Society. 2025. DOI: 10.1097/nan.0000000000000595.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.