BACKGROUND

After tooth extraction, inevitable resorption of the postextraction socket occurs. Placing an immediate implant does not fully preserve the bone integrity of the socket. Preservation techniques cannot avoid alveolar resorption. In residual atrophies, bone augmentation techniques are necessary for subsequent rehabilitation with implants. The aim of this study was to propose a protocol of immediate loading in short implants as an alternative to bone augmentation techniques, comparing the immediate versus conventional loading, evaluating peri-implant bone loss, the biological and prosthetic complications, the survival of the implant and prosthesis and the patient satisfaction after one year.

METHODS

This study consists of a randomized controlled clinical trial. For implant planning, periapical intraoral radiographs and Cone Beam Computed Tomography will be used. All patients will receive Straumann Group® (Basel, Switzerland) titanium-zirconia implants with a 4.1mm or 4.8mm diameter and a 4 mm or 6 mm length.

RESULTS

The expected results show similar or even minor bone loss, biological and prosthetic complications, identical or even better survival of the short implants with immediate loading, and greater satisfaction.

CONCLUSIONS

Short implants demonstrate similar survival to conventional length implants, with comparable or even minor biological and prosthetic complications and bone loss. Immediate loading gives satisfactory results similar to conventional loading, with similar biological and prosthetic complications, and generally depends on poor hygiene levels. Bone loss is even less, and the satisfaction increases.

Для цитирования: Galletti Fulvia, Galletti Cosimo, Gonzalez Terrats Rodrigo, D'Amico Cesare, De Angelis Francesca, Cervino Gabriele, Fiorillo Luca. Immediate versus conventional loading in short and ultra-short implants: a protocol design.. Minerva dental and oral science. 2024. DOI: 10.23736/s2724-6329.24.05057-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.