MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40780-023-00307-9

Медицинская библиотека · Journal of pharmaceutical health care and sciences · 2023

Poor removal of tedizolid during continuous hemodiafiltration: experiments using an in vitro continuous hemodiafiltration model.

Yoshikawa Satoshi, Yoshikawa Shinichi, Sato Akira, Matsumoto Tsukasa

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Tedizolid is an oxazolidinone anti-MRSA drug with included in the National Health Insurance Drug Price List in 2018. The effect of hemodialysis on tedizolid phosphate concentrations has been reported; pre-dialysis concentrations decreased by 10% compared to post- dialysis concentrations. However, the material of the dialysis membrane remains unknown. In addition, there have been no reports on the effects of continuous hemodiafiltration. In this study, we investigated the effects of continuous hemodiafiltration on tedizolid using two types of dialysis membranes made of different materials.

METHODS

The adsorption of tedizolid, linezolid, and vancomycin to two different dialysis membranes was investigated, and the clearance of each drug was calculated by experiments using an in vitro continuous hemodiafiltration model.

RESULTS

The adsorption of tedizolid, linezolid, and vancomycin on the dialysis membranes was examined, and no adsorption was observed. Experimental results from the continuous hemodiafiltration model showed that linezolid and vancomycin concentrations decreased over time: after two hours, the respective decreases were 26.48 ± 7.14% and 28.51 ± 2.32% for polysulfone membranes, respectively. The decrease was 23.57 ± 4.95% and 28.73 ± 5.13% for the polymethylmethacrylate membranes, respectively. These results suggested that linezolid and vancomycin were eliminated by continuous hemodiafiltration. In contrast, tedizolid phosphate and tedizolid concentrations decreased slightly in the polysulfone and polymethylmethacrylate membranes. The decrease in concentrations were 2.10 ± 0.77% and 2.97 ± 0.60% for the polysulfone membranes, respectively. For the polymethylmethacrylate membranes, the decrease in concentration were 2.01 ± 0.88% and 1.73 ± 0.27%, respectively.

CONCLUSION

These results suggested that tedizolid should not be considered for dose control during continuous hemodiafiltration.

Для цитирования: Yoshikawa Satoshi, Yoshikawa Shinichi, Sato Akira, Matsumoto Tsukasa. Poor removal of tedizolid during continuous hemodiafiltration: experiments using an in vitro continuous hemodiafiltration model.. Journal of pharmaceutical health care and sciences. 2023. DOI: 10.1186/s40780-023-00307-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.