DOI 10.1097/j.jcrs.0000000000001658

Медицинская библиотека · Journal of cataract and refractive surgery · 2025

Multiformula Prediction Range: a univariate predictor of IOL Power Calculation Accuracy.

Romero Daniel, Cárceles Montoya Alicia, Alió Jorge L, Moya Martínez Alejandro, Tarazona Jaimes Claudia, Martínez-Toldos Jose Juan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to evaluate the influence of range between the predictions of 5 different calculation formulas in IOL power calculation accuracy.

SETTINGS: General University Hospital of Elche, Spain.

DESIGN

Retrospective Sequential Cohort.

METHODS

In this retrospective sequential cohort, the LenStar LS900 (Haag-Streit, Koeniz, Switzerland) was used for the preoperative biometry. The predicted spherical equivalent refraction of the implanted IOL were calculated for 5 different formulas: Barrett Universal II, Emmetropia Verifying Optical (EVO) 2.0, Hill RBF-3.0, Kane, PEARL-DGS. Multiformula Prediction Range was defined as the range of the refractive error predicted by the 5 formulas. According to the median of the Multiformula Prediction Range the sample was divided into a low and high spread group (LS and HS respectively).

RESULTS

278 eyes were included. The standard deviation of the prediction error was significantly lower in the LS group for all included formulas. For the Barrett Universal II, EVO 2.0, RBF-3.0, Kane and PEARL-DGS formulae, the median absolute error (MdAE) was significantly lower in the LS group compared to the HS group (p-values of 0.001, 0.027, 0.004, 0.028 and 0.035, respectively). The percentage of eyes within the ±0.50D PE range was significantly higher in the LS group for all five analyzed formulas.

CONCLUSIONS

Multiformula Prediction Range can be a novel univariate predictor of IOL power calculation accuracy and a potential determinant for identifying patient suitable for immediate sequential cataract surgery. Accuracy was consistently higher for all five included formulas in the Low Spread group.

Для цитирования: Romero Daniel, Cárceles Montoya Alicia, Alió Jorge L, Moya Martínez Alejandro, Tarazona Jaimes Claudia, Martínez-Toldos Jose Juan. Multiformula Prediction Range: a univariate predictor of IOL Power Calculation Accuracy.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001658.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.