m+Medelevator.RU
← Поиск публикаций
Renal failure · 2019

99mTc-MIBI SPECT/CT imaging had high sensitivity in accurate localization of parathyroids before parathyroidectomy for patients with secondary hyperparathyroidism.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zeng Ming, Liu Wei, Zha Xiaoming, Tang Shaowen, Liu Jin, Yang Guang, Mao Huijuan, Yu Xiangbao, Sun Bin, Zhang Bo, Ouyang Chun, Zhang Lina, Guo Jing, Wang Jing, Huang Yaoyu, Purrunsing Yogendranath, Qian Hanyang, Wang Ningning, Xing Changying

Аннотация

Purpose: Accurate preoperative parathyroid localization is important for successful parathyroidectomy (PTX). The aim of our study was to investigate whether SPECT/CT has enhanced effect in preoperative localization of parathyroids. Methods: In our retrospective cohort study, we evaluated the effects of technetium-99m methoxyisobutylisonitrile-single-photon emission computed tomography/computed tomography (99mTc-MIBI SPECT/CT) on preoperative parathyroid localization for 645 secondary hyperparathyroidism (SHPT) patients. Among them, 569 successful PTX patients were divided into group A (received 99mTc-MIBI scintigraphy, n = 175) and group B (received 99mTc-MIBI scintigraphy and SPECT/CT imaging, n = 394). Sensitivity, specificity, and consistency of two imaging methods in preoperative localization of parathyroids were compared. Results: Overall sensitivity and consistency were higher in group B, while there was no difference in specificity between the two groups. In group A, the sensitivity of 99mTc-MIBI was 50.00%, 77.11%, 61.76%, and 76.54% in the right upper gland (RU), right lower gland (RL), left upper gland (LU), and left lower gland (LL) subgroups, while the consistency was 52.00%, 76.57%, 61.71%, and 75.43%, respectively. In group B, the sensitivity of 99mTc-MIBI with SPECT/CT was 69.39%, 90.03%, 78.07%, and 84.27%, and the consistency was 69.54%, 88.32%, 78.43%, and 84.26%, respectively. The sensitivity and consistency in lower glands were higher than in upper glands in both groups. Sensitivity for eutopic parathyroid was higher in group B, while there was no difference for ectopic parathyroid. Conclusions: 99mTc-MIBI SPECT/CT can increase the sensitivity and consistency of preoperative localization of eutopic parathyroid glands, and it can accurately locate ectopic parathyroid without sensitivity improvement.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты