MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/152660280301000524

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2003

Clinical experience with retrievable Günther Tulip vena cava filters.

Wicky Stephan, Doenz Francesco, Meuwly Jean-Yves, Portier François, Schnyder Pierre, Denys Alban

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report clinical experience with retrievable Günther Tulip filters from implantation to retrieval and their status in nonretrieved situations.

METHODS

Seventy-five Günther Tulip filter implantations were performed in 71 patients (43 women; mean age 55 years). Indications for filter placement were pulmonary embolism (PE) or iliofemoral deep vein thrombosis (DVT) in patients with a contraindication to anticoagulation (43, 61%) or perioperative PE prophylaxis (28, 39%) in patients with confirmed iliofemoral DVT. Retrieval procedures were planned for each patient. Patients with nonretrieved filters were followed with plain radiography and duplex sonography.

RESULTS

Technical success of filter insertion was 97.3% (73/75). Eighteen (25%) patients died from unrelated causes prior to retrieval attempts, and 6 other patients were too critically ill for a retrieval procedure. Of 49 (67%) planned retrieval attempts, 14 (19%) filters could not be removed owing to large trapped thrombi. The mean implantation period for the 35 (48%) retrieved filters was 8.2 days (range 1-13). Delivery tilt was observed in 12 (16%) filters and during retrieval attempts in 1 more case. For 9 nonretrieved filters, tilt and migration were observed in 22% at a mean follow-up of 30 months, but no venous thrombosis was assessed.

CONCLUSIONS

Our data confirm the clinical efficacy of the Günther Tulip filter during implantation and the feasibility of its retrieval. Further long-term follow-up should be conducted on nonretrieved filters to confirm our results.

Для цитирования: Wicky Stephan, Doenz Francesco, Meuwly Jean-Yves, Portier François, Schnyder Pierre, Denys Alban. Clinical experience with retrievable Günther Tulip vena cava filters.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2003. DOI: 10.1177/152660280301000524.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.