m+Medelevator.RU
← Поиск публикаций
Biosensors · 2026

An LSPR-Active AuNP-Silicone Hydrogel Contact Lens for Continuous Ocular Strain Sensing: From Engineering Design to In Vivo Validation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tang Yu, Meng Luhua, Liu Yun, Ma Xiang

Аннотация

Continuous intraocular pressure (IOP) monitoring is crucial for glaucoma management. Currently, traditional static IOP measurements often fail to detect circadian fluctuations, leading to a clinical dilemma where "normal IOP" is observed despite persistent visual field deterioration. This study presents a wireless, passive localized surface plasmon resonance (LSPR) sensing platform integrated into flexible silicone hydrogel contact lenses. Gold nanoparticles (AuNPs), synthesized via the sodium citrate reduction method, were incorporated into the lens periphery using a "swelling-induced nano-doping" technique to transduce IOP-induced corneal strain into detectable spectral shifts. Ex vivo porcine eye investigations established a physical mapping model, confirming significant LSPR peak wavelength response trends in correlation with IOP variations (10-50 mmHg) and corneal curvature changes. Subsequent 21-day in vivo rabbit studies demonstrated excellent ocular surface biocompatibility; quantitative histopathological analysis (HE, PAS, and Ki67 staining) revealed no significant adverse alterations in corneal endothelial cell density or conjunctival goblet cell function compared to control groups (p > 0.05). Furthermore, the platform maintained high structural integrity and anterior segment tolerance under transient high-IOP conditions. While currently a proof-of-concept, these results indicate that the LSPR-active hybrid system effectively captures dynamic IOP fluctuation patterns as an optical response to acute interventions, providing a foundational engineering path for next-generation, battery-free wearable diagnostics in personalized glaucoma care without the need for built-in electronics.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты