Prevalence and prediction of higher estimated gastric content in parturients at full cervical dilatation: A prospective cohort study.

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Desgranges François-Pierrick, Simonin Marine, Barnoud Sophie, Zieleskiewicz Laurent, Cercueil Eloise, Erbacher Julien, Allaouchiche Bernard, Chassard Dominique, Bouvet Lionel

Аннотация

BACKGROUND: Emergent obstetrical procedures may require general anaesthesia in parturients at full cervical dilatation or immediately after vaginal birth. This study aimed to determine the prevalence and the predictive factors of higher estimated gastric content in parturients at full cervical dilatation with epidural analgesia and allowed to drink during the labour, and to assess the ability of the antral area measured in the semirecumbent position (SR-CSA) to identify higher estimated gastric content in this setting.

METHODS: This prospective observational study was conducted between December 2016 and July 2017. Ultrasonographic examination of the antrum was performed at full cervical dilatation, within the hour preceding the beginning of expulsive efforts. Higher estimated gastric content was defined when solid content was observed and/or if the calculated gastric fluid volume was >1.5 mL/kg.

RESULTS: Seventeen of 62 parturients (27%) presented higher estimated gastric content. Maximal pain intensity during the last hour of labour and time interval between the insertion of the epidural catheter and ultrasonographic examination were significantly increased in parturients with higher estimated gastric content. The threshold value of the SR-CSA to identify a higher estimated gastric content was 393 mm2 , with sensitivity = 88% and specificity = 87%.

CONCLUSION: Around a quarter of parturients with epidural analgesia and free access to clear fluids during labour presented higher estimated gastric content at full cervical dilatation. The SR-CSA may be of interest for the fast ultrasound assessment of the gastric content status in case of emergent obstetrical procedures at full cervical dilatation.