The heart surgery forum · 2006
Evaluation of ascending aortic atherosclerosis with 16-multidetector computed tomography is useful before total endoscopic coronary bypass surgery.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Feuchtner Gudrun Maria, Schachner Thomas, Bonaros Nikolaos, Smekal Alexander, Mallouhi Ammar, Friedrich Guy J, Deutschmann Martin, Laufer Guenther, zur Nedden Dieter, Bonatti Johannes
Аннотация
BACKGROUND: The purpose of this study was to investigate the assessment of ascending aortic atherosclerosis with 16-multidetector computed tomography (16-MDCT) angiography prior to total endoscopic coronary artery bypass (TECAB) surgery.
METHODS: Forty-five patients were examined with electrocardiogram-gated, 16-MDCT angiography. The presence of atherosclerosis at the ascending aorta was graduated as severe (>50% of circumference) or as mild (<50% of circumference). Ascending aortic plaque composition was evaluated based on CT densities expressed as Hounsfield units (HU). TECABs using the Da Vinci telemanipulator were performed either on the arrested heart (n = 39) with an intra-aortic cardiopulmonary bypass (CPB) perfusion device or on the beating heart (n = 6) in patients with severe atherosclerosis.
RESULTS: The presence of mild atherosclerosis at the ascending aorta (11/39) was associated with intra-aortic CPB perfusion device-related difficulties such as intra-aortic balloon migration (BM) or balloon rupture (P = .007) in arrested heart TECABs. The CT density of atherosclerotic plaque in patients with BM was mean 58 HU +/- 51 standard deviation (SD), suggesting noncalcifying plaque. In patients without BM, CT density of plaque was mean 526 HU +/- 306 SD corresponding to calcifying plaque (P < .001). Balloon rupture occurred in 2 patients who had calcifying plaque at the ascending aorta.
CONCLUSION: Evaluation of ascending aortic atherosclerosis with 16-MDCT angiography is useful prior to TECAB surgery. Even mild atherosclerosis of the ascending aorta is associated with intraoperative difficulties regarding the remote-access perfusion system that is used for arrested heart TECAB surgery.
METHODS: Forty-five patients were examined with electrocardiogram-gated, 16-MDCT angiography. The presence of atherosclerosis at the ascending aorta was graduated as severe (>50% of circumference) or as mild (<50% of circumference). Ascending aortic plaque composition was evaluated based on CT densities expressed as Hounsfield units (HU). TECABs using the Da Vinci telemanipulator were performed either on the arrested heart (n = 39) with an intra-aortic cardiopulmonary bypass (CPB) perfusion device or on the beating heart (n = 6) in patients with severe atherosclerosis.
RESULTS: The presence of mild atherosclerosis at the ascending aorta (11/39) was associated with intra-aortic CPB perfusion device-related difficulties such as intra-aortic balloon migration (BM) or balloon rupture (P = .007) in arrested heart TECABs. The CT density of atherosclerotic plaque in patients with BM was mean 58 HU +/- 51 standard deviation (SD), suggesting noncalcifying plaque. In patients without BM, CT density of plaque was mean 526 HU +/- 306 SD corresponding to calcifying plaque (P < .001). Balloon rupture occurred in 2 patients who had calcifying plaque at the ascending aorta.
CONCLUSION: Evaluation of ascending aortic atherosclerosis with 16-MDCT angiography is useful prior to TECAB surgery. Even mild atherosclerosis of the ascending aorta is associated with intraoperative difficulties regarding the remote-access perfusion system that is used for arrested heart TECAB surgery.