Pinhole versus parallel-hole collimators for parathyroid imaging: an intraindividual comparison.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tomas Maria B, Pugliese Paul V, Tronco Gene G, Love Charito, Palestro Christopher J, Nichols Kenneth J

Аннотация

UNLABELLED: This study was undertaken to determine the effects of collimators on the accuracy of preoperative sestamibi parathyroid imaging of the neck.

METHODS: Forty-nine patients with primary hyperparathyroidism underwent preoperative (99m)Tc-sestamibi parathyroid imaging. The protocol included early and late pinhole and parallel-hole imaging. One experienced nuclear physician, without knowledge of other test results or final diagnoses, interpreted studies. For both pinhole and parallel-hole images, focally increased sestamibi accumulation outside the normal tracer biodistribution that persisted or increased in intensity from early to late images was interpreted as positive for a parathyroid lesion. Final diagnoses were operatively confirmed in all patients.

RESULTS: Fifty-four parathyroid lesions were resected from the 49 patients. Forty-five patients had single-gland disease. Four patients had multigland disease: 3 had 2 lesions and 1 had 3 lesions. Median lesion weight was 840 mg. Pinhole imaging was significantly more sensitive than parallel-hole imaging (89% vs. 56%; P = 0.0003) for all 54 lesions. Specificity did not significantly differ between pinhole and parallel-hole imaging (93% vs. 96%, P = 0.29). Pinhole imaging was significantly more sensitive than parallel-hole imaging for lesions above (100% vs. 68%, P = 0.003) and below (77% vs. 42%, P = 0.03) the median weight and for single-gland disease (96% vs. 67%, P = 0.001). Pinhole imaging also was more sensitive for multigland disease, although the difference was only marginally significant (55% vs. 0%, P = 0.037).

CONCLUSION: Because sensitivity is significantly higher, sestamibi parathyroid imaging of the neck should be performed with a pinhole collimator.