The Journal of invasive cardiology · 2020

Urologic Complications in Patients Receiving Indwelling Urinary Catheters During Transcatheter Aortic Valve Replacement.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lampert Joshua, Finn Matthew T, Kantor Alex, Akkoc Deniz, Chen Shmuel, Brandwein Russel, Fidlow Kathryn, Liao Ming, Khalique Omar, Hahn Rebecca T, Vahl Torsten P, George Isaac, Kirtane Ajay, Leon Martin B, Kodali Susheel K, Nazif Tamim M

Аннотация

OBJECTIVES: The minimalist approach to transcatheter aortic valve replacement (TAVR) focuses on avoiding extraneous invasive measures. Data describing the clinical impact of routine indwelling urinary catheter (IUC) in TAVR patients is limited. We sought to examine outcomes after IUC placement in patients undergoing TAVR.

METHODS: We performed a retrospective analysis of 773 consecutive patients undergoing TAVR between 2011 and 2015. Patients were excluded who did not receive an IUC, had a pre-existing IUC, had renal replacement therapy, or underwent non-transfemoral TAVR. Patients were classified by presence of the composite of in-hospital urologic adverse events (UAEs), defined as urinary retention, IUC reinsertion, discharge with IUC, new hematuria, or urinary tract infection (UTI). The primary study endpoint was all-cause mortality at 1 year.

RESULTS: A total of 520 patients met study criteria and were analyzed. The incidence of UAE was 28.6%. Urinary retention after IUC removal occurred in 14.6% of patients. UTIs occurred in 6.5% and acute kidney injury occurred in 13.6% of IUC patients. UAE was associated with an increased rate of 30-day and 1-year all-cause mortality (hazard ratio [HR], 2.84; 95% confidence interval [CI], 1.09-7.35; P=.02 and HR, 1.96; 95% CI, 1.22-3.16; P<.01, respectively). After multivariable adjustment for important baseline differences, UAEs were associated with significantly greater hazard of 1-year mortality (adjusted HR, 1.79; 95% CI, 1.07-2.99; P=.03) but not 30-day mortality (adjusted HR, 1.96; 95% CI, 0.67-5.49; P=.22).

CONCLUSION: UAEs were frequent in patients receiving an IUC during TAVR and were associated with substantial morbidity, as well as longer hospital stay. Further research is required to establish whether avoidance of IUC as a component of the minimalist approach will reduce UAEs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты