MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11096-019-00793-8

Медицинская библиотека · International journal of clinical pharmacy · 2019

Coeliac disease detection with an IgA/IgG-deamidated gliadin peptide based point of care test in community pharmacies.

Lau Michelle S, Sanders David S

СтатьяПеревод пока не подготовлен

Аннотация

Background Coeliac disease affects 1% of the population, but 75% remain undiagnosed. Objective To conduct a case finding feasibility and efficacy study for the detection of coeliac disease in community pharmacies. Setting Six community pharmacies across Sheffield, UK. Method A prospective study was performed using a point of care test, Simtomax® (IgA/IgG-deamidated gliadin peptide) (C-test) in pharmacies. Pharmacy customers with symptoms suggestive of or risk factors for coeliac disease were tested with the C-test. Positive individuals were referred for a gastroscopy with duodenal biopsies alongside conventional serology. People with known coeliac disease, those on a gluten free diet or those who were investigated for coeliac disease were excluded. Main outcome measure The case detection rate and the uptake rate of the C-test and gastroscopies. Results Five-hundred participants fulfilled the inclusion criteria and were tested with the C-test (369 females, 73.8%; age range 18-87, median 49). The C-test uptake rate was 63%, and the positive rate was 7.2% (36/500). Twenty-seven positive participants (75%) underwent further investigations, confirming three new cases of coeliac disease (0.6%). Conclusion It was feasible to use the C-test as a case finding tool in pharmacies. There was good uptake for the C-test, although the case detection rate and the test specificity were low. Based on this, the C-test has a limited role in case finding in a community pharmacy setting.

Для цитирования: Lau Michelle S, Sanders David S. Coeliac disease detection with an IgA/IgG-deamidated gliadin peptide based point of care test in community pharmacies.. International journal of clinical pharmacy. 2019. DOI: 10.1007/s11096-019-00793-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.