MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/nu10101444

Медицинская библиотека · Nutrients · 2018

The Significance of Low Titre Antigliadin Antibodies in the Diagnosis of Gluten Ataxia.

Hadjivassiliou Marios, Grünewald Richard A, Sanders David S, Zis Panagiotis, Croal Iain, Shanmugarajah Priya D, Sarrigiannis Ptolemaios G, Trott Nick, Wild Graeme, Hoggard Nigel

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with gluten ataxia (GA) without enteropathy have lower levels of antigliadin antibodies (AGA) compared to patients with coeliac disease (CD). Magnetic Resonance Spectroscopy (NAA/Cr area ratio) of the cerebellum improves in patients with GA following a strict gluten-free diet (GFD). This is associated with clinical improvement. We present our experience of the effect of a GFD in patients with ataxia and low levels of AGA antibodies measured by a commercial assay.

METHODS

Consecutive patients with ataxia and serum AGA levels below the positive cut-off for CD but above a re-defined cut-off in the context of GA underwent MR spectroscopy at baseline and after a GFD.

RESULTS

Twenty-one consecutive patients with GA were included. Ten were on a strict GFD with elimination of AGA, 5 were on a GFD but continued to have AGA, and 6 patients did not go on a GFD. The NAA/Cr area ratio from the cerebellar vermis increased in all patients on a strict GFD, increased in only 1 out of 5 (20%) patients on a GFD with persisting circulating AGA, and decreased in all patients not on a GFD.

CONCLUSION

Patients with ataxia and low titres of AGA benefit from a strict GFD. The results suggest an urgent need to redefine the serological cut-off for circulating AGA in diagnosing GA.

Для цитирования: Hadjivassiliou Marios, Grünewald Richard A, Sanders David S, Zis Panagiotis, Croal Iain, Shanmugarajah Priya D, Sarrigiannis Ptolemaios G, Trott Nick, Wild Graeme, Hoggard Nigel. The Significance of Low Titre Antigliadin Antibodies in the Diagnosis of Gluten Ataxia.. Nutrients. 2018. DOI: 10.3390/nu10101444.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.