m+Medelevator.RU
← Поиск публикаций
Transfusion · 2014

A longitudinal study of Babesia microti infection in seropositive blood donors.

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Leiby David A, Johnson Stephanie T, Won Kimberly Y, Nace Eva K, Slemenda Susan B, Pieniazek Norman J, Cable Ritchard G, Herwaldt Barbara L

Аннотация

BACKGROUND: Babesia infection is caused by intraerythrocytic tick-borne parasites. Cases of transfusion-transmitted babesiosis have been increasingly recognized. To date, no Babesia test has been licensed for screening US blood donors. We conducted a longitudinal study to assess the course and markers of Babesia infection among seropositive donors identified in a seroprevalence study.

STUDY DESIGN AND METHODS: Eligible donors had B. microti indirect fluorescent antibody (IFA) titers of 64 or greater. Enrollees were monitored up to 3 years, by IFA and three methods for evidence of parasitemia: B. microti nested polymerase chain reaction (PCR) analysis (at two laboratories), hamster inoculation, and blood-smear examination.

RESULTS: Among 115 eligible donors, 84 (73%) enrolled. Eighteen enrollees (21%) had evidence of parasitemia for 30 total specimens (17% of 181), which were collected in 9 different months and tested positive by various approaches: PCR (25 specimens/16 persons), hamster inoculation (13 specimens/8 persons), and blood smear (one specimen positive by all three approaches). Overall, 14 persons had one or more specimen with positive PCR results at both laboratories (12 persons) and/or had parasitologically confirmed infection (eight persons). Three of nine persons who had more than one specimen with evidence of parasitemia had nonconsecutive positives. Several enrollees likely had been infected at least 1 year when their last positive specimen was collected. The final three specimens for seven persons tested negative by all study methods, including IFA.

CONCLUSION: Seropositive blood donors can have protracted low-level parasitemia that is variably and intermittently detected by parasitologic and molecular methods. Donor-screening algorithms should include serologic testing and not solely rely on molecular testing.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты