m+Medelevator.RU
← Поиск публикаций
Journal of cardiothoracic surgery · 2024

Analysis of risk factors for complications in echocardiography-guided percutaneous intramyocardial septal radiofrequency ablation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Hanzhi, Cheng Jifang, Chen Qi, Pu Zhaoxia, Li Huajun

Аннотация

BACKGROUND: The feasibility of percutaneous intramyocardial septal radiofrequency ablation (PIMSRA) for the treatment of hypertrophic obstructive cardiomyopathy (HOCM) has been previously reported. However, limited investigation has been conducted regarding the complications associated with this procedure.

OBJECTIVE: This study aims to analyze the risk factors affecting the occurrence of complications during PIMSRA, such as pericardial effusion, ventricular premature beats, and interventricular septal perforation. In this study, the optimal cut-off values for these risk factors are also explored, and corresponding strategies for prevention are proposed.

METHODS: A total of 101 patients diagnosed with HOCM who underwent the PIMSRA procedure from 2021 to 2022 were included in this retrospective analysis. Patients were classified into subgroups with or without complications based on procedural records. Univariate and multivariate regression analyses were conducted to identify independent risk factors for complications during the PIMSRA procedure.

RESULTS: There were 48 patients with complications and 53 patients without complications. The heart rate at the start of the procedure and the maximum left ventricular outflow tract gradient (LVOTG) were independent risk factors related to PIMSRA complications. The optimal cut-off values for predicting complication occurrence were a heart rate > 49 bpm at the start of the procedure (OR: 3.79, 95% CI: 1.64-8.78, p = 0.002) and a maximum LVOTG > 92 mmHg (OR: 2.57, 95% CI: 1.15-5.75, p = 0.022), respectively.

CONCLUSIONS: The occurrence of PIMSRA complications is primarily associated with the heart rate at the start of the procedure and the maximum LVOTG. It is recommended to establish a comprehensive control plan to minimize the risk of complications during PIMSRA procedures.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты