MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2024.131939

Медицинская библиотека · International journal of cardiology · 2024

Contrast-free left atrial appendage occlusion in patients using the LAMBRE™ device.

Vij Vivian, Ruf Tobias Friedrich, Thambo Jean-Benoit, Vogt Lara, Al-Sabri Saddam M A, Nelles Dominik, Schrickel Jan-Wilko, Beiert Thomas, Nickenig Georg, von Bardeleben Ralph Stephan, Iriart Xavier, Sedaghat Alexander

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device.

METHODS

The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed.

RESULTS

Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118).

CONCLUSION

Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.

Для цитирования: Vij Vivian, Ruf Tobias Friedrich, Thambo Jean-Benoit, Vogt Lara, Al-Sabri Saddam M A, Nelles Dominik, Schrickel Jan-Wilko, Beiert Thomas, Nickenig Georg, von Bardeleben Ralph Stephan, Iriart Xavier, Sedaghat Alexander. Contrast-free left atrial appendage occlusion in patients using the LAMBRE™ device.. International journal of cardiology. 2024. DOI: 10.1016/j.ijcard.2024.131939.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.