BACKGROUND

Interruption in Doppler intrarenal venous flow (IRVF) has been used in assessing renal congestion and in the prediction of prognosis of cardiovascular diseases. However, there is a paucity of pathophysiological knowledge, so we aimed to clarify the determinants of IRVF interruption.

METHODS AND

RESULTS

Intrarenal Doppler studies were performed within 24 h before right-side catheterization studies. The interruption in IRVF in 73 patients was divided into a continuous pattern, and 4 discontinuous types based on the timing of interruption. Type 1, with an interruption in early systole, was associated with a-wave elevation of right atrial pressure (RAP). Type 2, with an interruption in early diastole, was associated with v-wave elevation, tricuspid regurgitation (TR), and right ventricular dysfunction. Both Type 1 and 2 were observed even in the normal range of mean RAP. Type 3, with an interruption throughout systole, was observed in advanced right heart failure patients with markedly elevated RAP, particularly elevated x-descend and atrial fibrillation. Finally, Type 4, with limited flow at systole, was observed in 2 of the patients with pulmonary arterial hypertension.

CONCLUSIONS

IRVF interruption was closely related to RAP elevation at each specific point of the cardiac cycle rather than to mean RAP levels, suggesting that the characteristics of IRVF mirror right-sided heart hemodynamics, not mean RAP.

Для цитирования: Seo Yoshihiro, Iida Noriko, Yamamoto Masayoshi, Ishizu Tomoko, Ieda Masaki, Ohte Nobuyuki. Doppler-Derived Intrarenal Venous Flow Mirrors Right-Sided Heart Hemodynamics in Patients With Cardiovascular Disease.. Circulation journal : official journal of the Japanese Circulation Society. 2020. DOI: 10.1253/circj.cj-20-0332.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.