m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular medicine (Hagerstown, Md.) · 2021

Arrhythmic event prediction in patients with heart failure and reduced ejection fraction.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Santangelo Gloria, Bursi Francesca, Negroni Maria S, Gentile Domitilla, Provenzale Giovanni, Turriziani Laura, Zambelli Daniel L, Fiorista Lorenzo, Bacchioni Giuseppe, Massironi Laura, Tarricone Diego G, Carugo Stefano

Аннотация

AIMS: Implantable cardioverter defibrillator (ICD) is an effective treatment to reduce mortality in patients with symptomatic heart failure and left ventricular ejection fraction (LVEF) 35% or less. LVEF presents a low sensitivity for predicting arrhythmic events. Aim of this study was to identify predictors of sustained ventricular arrhythmias (SVAs), overall and according to the cause of heart failure.

METHODS: Single-center, retrospective, cohort study of 193 patients (51 nonischemic and 142 ischemic) with chronic heart failure and LVEF less than 35% who had received ICD for primary prevention of sudden cardiac death. We collected clinical data, echocardiographic parameters and SVAs detected by the ICD.

RESULTS: During a median follow-up of 1440 days, 32 (16.2%) patients had SVAs. SVAs incidence was similar in patients with nonischemic (15.6%) and ischemic cause of heart failure (16.9%). Hypertension, diabetes, chronic renal failure, atrial fibrillation, chronic obstructive pulmonary disease, New York Heart Association class at least III were predictors at univariate analysis of SVAs. A clinical score, assigning one point to each of these variables, was associated with a significantly increased risk of SVAs [odds ratio for each point increase = 1.92, 95% confidence interval 1.40-2.65, P < 0.0001, area under the curve (AUC) 0.73], with 72% sensitivity and 60% specificity for a cutoff at least three and remained significant in nonischemic (AUC 0.84) and ischemic (AUC 0.68) patients.

CONCLUSION: Our study shows the benefit of ICD implantation in primary prevention and its independency of cause. A simple clinical score, based on comorbidities, identifies patients with more benefits from ICD implantation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты