MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics15070875

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2025

Grid-Based Software for Quantification of Diabetic Retinal Nonperfusion on Ultra-Widefield Fluorescein Angiography.

Omari Amro, Cooper Caitlyn, Desjarlais Eric B, Cook Maverick, Abalem Maria Fernanda, Andrews Chris A, Joltikov Katherine, Khan Rida M, Chen Andy, DeOrio Andrew, Gardner Thomas W, Paulus Yannis M, Jayasundera K Thiran

СтатьяПеревод пока не подготовлен

Аннотация

Background/

Objectives

Fluorescein angiography (FA) is essential for diagnosing and managing diabetic retinopathy (DR) and other retinal vascular diseases and has recently demonstrated potential as a quantitative tool for disease staging. The advent of ultra-widefield (UWF) FA, allowing visualization of the peripheral retina, enhances this potential. Retinal hypoperfusion is a critical risk factor for proliferative DR, yet quantifying it reliably remains a challenge.

Methods

This study evaluates the efficacy of the Michigan grid method, a software-based grading system, in detecting retinal hypoperfusion compared to the traditional freehand method. Retinal UWF fluorescein angiograms were obtained from 50 patients, including 10 with healthy retinae and 40 with non-proliferative DR. Two independent, masked graders quantified hypoperfusion in each image using two methods: freehand annotation and a new Michigan grid method.

Results

Using the Michigan grid method, Grader 1 identified more ungradable segments, while Grader 2 identified more perfused and nonperfused segments. Cohen's weighted kappa indicated substantial agreement, which was slightly higher for the entire retina (0.711) compared to the central retinal area (0.686). The Michigan grid method shows comparable or slightly improved inter-rater reliability compared to the freehand method.

Conclusions

This study demonstrates a new Michigan grid method for the evaluation of FA for hypoperfusion while highlighting ongoing challenges in achieving consistent and objective retinal nonperfusion assessment, underscoring the need for further refinement and the potential integration of automated approaches.

Для цитирования: Omari Amro, Cooper Caitlyn, Desjarlais Eric B, Cook Maverick, Abalem Maria Fernanda, Andrews Chris A, Joltikov Katherine, Khan Rida M, Chen Andy, DeOrio Andrew, Gardner Thomas W, Paulus Yannis M, Jayasundera K Thiran. Grid-Based Software for Quantification of Diabetic Retinal Nonperfusion on Ultra-Widefield Fluorescein Angiography.. Diagnostics (Basel, Switzerland). 2025. DOI: 10.3390/diagnostics15070875.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.