BACKGROUND

Acute studies in cardiac resynchronization therapy (CRT) showed that hemodynamic effects may depend on the coronary sinus (CS) lead position. However, there are no data on the longterm effect of CS lead position.

METHODS

In 45 heart failure patients with left bundle branch block and QRS >150 ms (age 59+/-10 years, 17 dilative cardiomyopathy, 23 ischemic, 5 valvular), biventricular pacemakers were implanted. CS leads were positioned in posterior (P, n=15), lateral (L, n=19) or, if no other option available, anterior (A, n=11) side branches. Before and 6 months after implantation, clinical state, echocardiography, brain natriuretic peptide (BNP) and right heart catheterization were evaluated.

RESULTS

Baseline parameters were similar between groups. After 6 months, there were 32/34 responders in groups P and L compared to 7/11 responders in group A (94 vs groups P and L: Arterial pressure +8 and +9% vs +2%; PCWP -23 and -15% vs -4%, pulmonary pressure -18 and -12% vs -3% (p<0.01 for A vs P+L); cardiac index +21 and +12% vs +11% (p=0.03 for A vs P). BNP was reduced by 55, 35, and 27% (p=0.05 for A vs P). Ejection fraction increased in P and L by 40 and 41%, respectively, but only by +19% in A (p<0.03 for A vs P+L).

CONCLUSION

Chronic CRT improves ejection fraction, BNP and hemodynamic measurements predominantly in patients with lateral and posterior CS lead positions. Anterior lead positions should be avoided.

Для цитирования: Nägele H, Hashagen S, Azizi M, Behrens S, Castel M A. Long-term hemodynamic benefit of biventricular pacing depending on coronary sinus lead position.. Herzschrittmachertherapie & Elektrophysiologie. 2006. DOI: 10.1007/s00399-006-0533-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.